Panasonic PT-D1000 Specifications page 60

Panasonic pt-d1000: user guide
Table of Contents

Advertisement

2.151. SELF CHECK Information
Hexadecimal
Remarks
Response (Callback)
In the period when the command can be accepted
Hexadecimal
Acceptability
SECURITY
Yes
Parameters (*2—*17)
Bit
Name
0
Temperature warning (IN)
1
Temperature warning (OPT)
2
Temperature warning (OUT)
3
Low temperature warning (OPT)
4
Temperature error (IN)
5
Temperature error (OPT)
6
Temperature error (OUT)
7
Low temperature error (OPT)
8
Lamp 1 operating time warning
9
Lamp 2 operating time warning
10
Lamp 3 operating time warning
11
Lamp 4 operating time warning
12
Lamp 1 operating time exceeded
13
Lamp 2 operating time exceeded
14
Lamp 3 operating time exceeded
15
Lamp 4 operating time exceeded
16
Lamp 1 going out
17
Lamp 2 going out
18
Lamp 3 going out
19
Lamp 4 going out
20
Lamp 1 lighting failure
21
Lamp 2 lighting failure
22
Lamp 3 lighting failure
23
Lamp 4 lighting failure
24
Lamp 1 not installed
25
Lamp 2 not installed
26
Lamp 3 not installed
27
Lamp 4 not installed
28
AC power supply voltage drop
warning (less than 90 V)
29
Lamp unit cover is not closed
30
31
02h
*1
STX
ID
Command
02h
*5
FEh
STX
ID
STNDBY
NO SIGNAL
Yes
Yes
Description
Intake air temperature is the specific value or higher.
Optical module (DMD surroundings) temperature is the
specific value or higher.
Exhaust air temperature is the specific value or higher.
Optical module (DMD surroundings) temperature is less than
the specific value.
Intake air temperature is the specific value or higher.
Optical module (DMD surroundings) temperature is the
specific value or higher.
Exhaust air temperature is the specific value or higher.
Optical module (DMD surroundings) temperature is less than
the specific value.
Lamp cumulative usage time is the specific value or longer.
Lamp cumulative usage time is the specific value or longer.
Lamp-Goes out after turning on.
Lamp ignition failure
Lamp not installed, or Lamp memory read failure
Lamp unit cover is not closed for 1 second or longer.
FEh
FEh
Option
FEh
*2
*3
SHUTTER
TEST PATTERN
Yes
Yes
60/62
03h
ETX
*4
*15
Parameters
REMOTE2
Yes
*16
*17
03h
Condition of Clear Bit
It is less than the specific
value.
It is less than the specific
value.
It is less than the specific
value.
It is the specific value or
higher.
It is less than the specific
value.
It is less than the specific
value.
It is less than the specific
value.
It is the specific value or
higher.
Lamp replacement
Executes the lamp
turning on processing.
MAIN POWER ON after
the lamp is installed, or
Lamp memory
initialization
POW ER ON after the lamp
unit cover is closed

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-dw10000Rs-232c

Table of Contents