3. Wiring the Power Inputs

The Upper Panel of the Industrial Managed Switch indicates an inlet power
socket and consists of one green terminal block connector with 6 contacts.
Please follow the steps below to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1,
or Contacts 5 and 6 for Power 2.
 DC 9-48V, AC 24V (IGS-6325-4T2X & IGS-6325-5X1T)
(Wiring methods also apply to IGS-6325-4T2X except different max. input current values)
Refer to the table below for the Input Voltage and Current Values for each
model
DC Input Voltage
Max. DC Input Current
AC Input Voltage
Max. AC Input Current
DI0
DI1 DO0 DO1
1 2 3 4 5 6
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
V1+
DC Input: 9-48V
, 4A max.
AC Input: 24V
, 2A max.
PWR1
Figure 3-1: IGS-6325-5X1T Upper Panel
IGS-6325-4T2X
9-48V DC
3A
24V AC
1.5A
GND
GND
V2+
Alarm
PWR2
9-48V DC
4A
24V AC
2A
IGS-6325-5X1T
5