Axis A1610-B User Manual page 26

Network door controller
Hide thumbs Also See for A1610-B:
Table of Contents

Advertisement

AXIS A1610-B Network Door Controller
Specifications
Configurable (Input
or Output)
Power connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.
Function
0 V DC (-)
DC input
UL: DC power to be supplied by a UL 294, UL 293 or UL 603 listed power supply, depending on application, with appropriate ratings.
12 V backup power input
For a backup solution using a battery with built-in charger. 12 V DC input.
UL: The connector has not been evaluated by UL.
Important
When the battery input is used, an external 3 A slow blow fuse must be connected in series.
Function
0 V DC (-)
Battery input
2, 4
Digital input – Connect to pin 1 or 3 to activate, or
leave floating (unconnected) to deactivate.
Digital output – Connect to pin 1 or 3 to activate, or
leave floating (unconnected) to deactivate. If used
with an inductive load, e.g., a relay, connect a diode
in parallel with the load, to protect against voltage
transients.
Pin
Notes
1
2
For powering controller when not using Power over
Ethernet.
Note: This pin can only be used as power in.
Pin
Notes
1
2
For powering the door controller when other power
sources are unavailable.
Note: This pin can only be used as battery power in.
For connection to UPS only.
26
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA
Specifications
0 V DC
10.5–28 V DC, max 36 W
Specifications
0 V DC
11– 13.7 V DC, max 36 W

Advertisement