Axis A1610-B User Manual page 16

Network door controller
Hide thumbs Also See for A1610-B:
Table of Contents

Advertisement

AXIS A1610-B Network Door Controller
The device interface
• All: Send both stateful and stateless messages as retained.
QoS: Select the desired level for the MQTT publication.
MQTT subscriptions
Add subscription: Click to add a new MQTT subscription.
Subscription filter: Enter the MQTT topic that you want to subscribe to.
Use device topic prefix: Add the subscription filter as prefix to the MQTT topic.
Subscription type:
• Stateless: Select to convert MQTT messages into a stateless message.
• Stateful: Select to convert MQTT messages into a condition. The payload is used as the state.
QoS: Select the desired level for the MQTT subscription.
Accessories
I/O ports
Use digital input to connect external devices that can toggle between an open and closed circuit, for example PIR sensors, door or
window contacts, and glass break detectors.
Use digital output to connect external devices such as relays and LEDs. You can activate connected devices through the VAPIX®
Application Programming Interface or in the device interface.
Port
Name: Edit the text to rename the port.
Direction:
indicates that the port is an input port.
you can click the icons to change between input and output.
Normal state: Click
Current state: Shows the current state of the port. The input or output is activated when the current state is different from the
normal state. An input on the device has an open circuit when it's disconnected or when there is a voltage above 1 V DC.
Note
During restart the output circuit is open. When the restart is complete, the circuit goes back to the normal position. If you
change any settings on this page, the output circuits go back to their normal positions regardless of any active triggers.
Supervised
: Turn on to make it possible to detect and trigger actions if someone tampers with the connection to digital
I/O devices. In addition to detecting if an input is open or closed, you can also detect if someone has tampered with it (that is, cut
or shorted). To supervise the connection requires additional hardware (end-of-line resistors) in the external I/O loop.
Logs
Reports and logs
open circuit, and
for closed circuit.
indicates that it's an output port. If the port is configurable,