Supermicro A+ Server AS-2015CS-TNR User Manual page 119

Table of Contents

Advertisement

Appendix B: System Specifications
Power Supply
PWS-1K23A-1R, 1000W/1200W redundant modules, 80Plus Platinum level*
AC Input
1000W: 100-127Vac / 15A-12A / 50-60Hz
1200W: 200-240Vac / 8.5A-7A / 50-60Hz
+12V
Max: 83A / Min: 0A (100Vac-127Vac)
Max: 100A / Min: 0A (200Vac-240Vac)
5V SB
Max: 4A / Min: 0A
*Full redundancy based on configuration and application load.
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)*
Non-operating Temperature: -40º to 60º C (-40º to 140º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
*Note: Operating Temperature based on confirgurations
Regulatory Compliance
FCC, ICES, CE, VCCI, RCM, UKCA, NRTL, CB
Applied Directives, Standards
EMC/EMI: 2014/30/EU (EMC Directive) CLASS A
Electromagnetic Compatibility Regulations 2016
FCC Part 15 Subpart B
ICES-003
VCCI-CISPR 32
AS/NZS CISPR 32
BS/EN55032
BS/EN55035
CISPR 32
CISPR 35
BS/EN 61000-3-2
BS/EN 61000-3-3
BS/EN 61000-4-2
BS/EN 61000-4-3
BS/EN 61000-4-4
BS/EN 61000-4-5
BS/EN 61000-4-6
BS/EN 61000-4-8
BS/EN 61000-4-11
Environment:
2011/65/EU (RoHS Directive)
EC 1907/2006 (REACH)
2012/19/EU (WEEE Directive)
California Proposition 65
Product Safety: 2014/35/EU (LVD Directive)
UL/CSA 62368-1 (USA and Canada)
Electrical Equipment (Safety) Regulations 2016
IEC/BS/EN 62368-1
Perchlorate Warning
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products
containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/
hazardouswaste/perchlorate"