Example Of Configurecmd - netvox R718CN2 User Manual

Wireless 2-gang thermocouple sensor for k/t/n type
Hide thumbs Also See for R718CN2:
Table of Contents

Advertisement

5.2 Example of ConfigureCmd

FPort:0x07
Bytes
1
CmdID
CmdID– 1 byte
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
Description
Device
ConfigReport
Req
ConfigReport
R718CK2
Rsp
R718CT2
ReadConfig
R718CN2
ReportReq
ReadConfig
ReportRsp
(1) Configure R718CK2 report parameters:
MinTime = 1min、MaxTime = 1min、BatteryChange = 0.1v、TemperatureChange = 1°C (10*0.1°C)
Downlink: 0116003C003C01000A0000
Response:
8116000000000000000000 (Configuration success)
8116010000000000000000 (Configuration failure)
(2) Read Configuration:
Downlink: 0216000000000000000000
Response:
8216003C003C01000A0000 (Current configuration)
1
DeviceType
Cmd
Device
ID
Type
MinTime
0x01
(2bytes Unit:s)
0x81
0x16
0x17
0x02
0x18
MinTime
0x82
(2bytes Unit:s)
3C(Hex) =60(Dec)
Var (Fix =9 Bytes)
NetvoxPayLoadData
NetvoxPayLoadData
MaxTime
BatteryChange
(2bytes Unit:s)
(1byte Unit:0.1v)
Status
(0x00_success)
Reserved
(9Bytes,Fixed 0x00)
MaxTime
BatteryChange
(2bytes Unit:s)
(1byte Unit:0.1v)
0A(Hex) = 10(Dec)
7
TemperatureChange
Reserved
(2byte Unit:0.1℃)
(2Bytes,Fixed 0x00)
Reserved
(8Bytes,Fixed 0x00)
TemperatureChange
Reserved
(2byte Unit:0.1℃)
(2Bytes,Fixed 0x00)