Download Print this page

Communication Cable Connections - M-system R7M-DAC16D-R Instruction Manual

Pnp discrete input & pnp transistor output module, 8 points each (modbus 115.2kbps)

Advertisement

COMMUNICATION CABLE CONNECTIONS

■ MASTER CONNECTION
Host PC
TERMINATOR
Tx+/Rx+
Tx–/Rx–
SG
Rx+
Rx–
Be sure to connect the terminating resistor included in the product package to the unit at both ends of transmission line.
The terminator must be connected across DA and DB.
The Host PC can be located other than at the extreme ends of transmission line.
EXAMPLE OF OPERATION MODES
■ MAINTAINED OUTPUT MODE
Example of Y0 is shown below.
OFF
Bit 0
OFF
Y0
■ MOMENTARY OUTPUT MODE
Y0 and Y1, Y2 and Y3, Y4 and Y5, Y6 and Y7 are respectively combined to realize momentary switching with one-shot output.
Bit 0, 2, 4, 6 are used to control each set of outputs, while Bit 1, 3, 5, 7 are unused.
An example of Bit 0 controlling Y0 and Y1 outputs sequentially is shown below.
1) Output data Bit 0 is turned from 0 to 1.
2) Following the rising edge of Bit 0, Y0 one-shot output turns ON for a fixed period of time (SW1 time setting).
3) Bit 0 is turned from 1 to 0.
4) Following the sinking edge of Bit 0, Y1 one-shot output turns ON for a fixed period of time (SW1 time setting).
OFF
Bit 0
OFF
Y0
Y1
Note: If Bit 0 receives multiple data during the one-shot output time period, the Y0 provides only the last output data received
within approx. 25 milliseconds after the period.
SEN TRONIC
Remote Unit
DA
DB
DG
SLD
FG
ON
OFF
ON
OFF
(1)
ON
(2) One-shot output
ON
OFF
056 222 38 18
mailbox@sentronic.com
AG
Remote Unit
TERMINATOR
DA
DB
DG
SLD
FG
(3)
OFF
OFF
(4) One-shot output
ON
OFF
EM-7803-AL Rev.4 P. 5 / 8
www.sentronic.com
R7M-DAC16D

Advertisement

loading

This manual is also suitable for:

R7m-dac16dR7 series