Auto Shut-Down

d
WARNING: This function automatically stops
the engine. Take extra care on the work and work
environment when using this function.
When the auto shut-down function is turned ON, the engine
automatically stops after the preset time at the state in which
the control shut-off lever is pulled. 30 seconds before the
engine stop, monitor (2) displays a message that engine
will be stopped and indicator (1) starts flashing. Also the
buzzer sounds. The buzzer sounds once at 30 seconds before,
continuously sounds from 15 seconds. The engine speed
decreases to the idling speed, and then stops after 15 seconds.
When the control shut-off lever is pushed or engine control
dial is operated before stopping the engine, the auto shut-
down is disabled and the engine will not stop.
IMPORTANT:
 Ensure that the ON or OFF status of auto shut-down
indicator (1). If the indicator is ON, the auto shut-
down function will be activated.
 When the engine stops by the auto shut-down
function, turn the key switch to OFF once and then
turn it to START to restart the engine. Do not leave
the machine after auto shut-down. Failure to do so
may discharge the batteries.
 When the key switch is turned to OFF position while
the auto shut-down function is ON, the setting will
be maintained. If the auto-idling function is required
to be turned OFF when starting the engine, consult
your authorized Hitachi dealer.
Operating Condition
 The auto shut-down function is ON.
 The engine is running.
 The pilot control shut-off lever is in the LOCK position.
 The overheat indicator is OFF.
 The engine control dial is not operated.
 The muffler filter is not in regenerating process.