Requirements On Water Quality - Sinclair STHERM SMH IRB Series Installation Manual

Monoblock inverter air to water heat pump
Table of Contents

Advertisement

Circulating water inlet/outlet of main unit
Cooling water inlet of water tank
Circulating water inlet/outlet of water tank
Hot water outlet of water tank
Code
01842800004P01
Retaining Plate Sub-Assy
70210087
70110066
0738280101
035033000012
Water Pipe Connector
06332800003
75042805
030059000120
Water inlet pipe sub-assy
05332800002
Drainage Pipe(Rubber)
70814016
2690280000502
0184280000502P
Notes
(a) Distance between indoor unit and water tank should not exceed 5m levelly and 3m vertically. If higher,
please contact with us. Water tank on lower and main unit on higher side is recommended.
(b) Prepare the materials according to the above joints dimension. If cut-off valve is installed outside the room,
PPR pipe is recommended to avoid freeze damage.
(c) Waterway pipelines can't be installed until water heater unit is fixed. Do not let dust and other sundries
enter into pipeline system during installation of connection pipes.
(d) After connection of all waterway pipelines, perform leakage test firstly. After that, perform heat preservation
of waterway system; meanwhile, pay more attention to valves and pipe joints. Ensure enough thickness of
insulated cotton. If necessary, install heating device for pipeline to prevent the pipeline from freezing.
(e) Hot water supplied from insulated water tank depends on pressure of water tap, so there must be supply of
tap water.
(f) During using, the cut-off valve of cooling water inlet of water tank should be kept normally on.

16.4 Requirements on water quality

Paramete
pH( 25°C)
Cloudy
Chloride
Fluoride
Iron
Sulphate
SiO
2
Hardness(count CaCO
Nitrate(count N)
Conductance(25°C)
Ammonia (count N)
Alkalinity(count CaCO
Sulfid
Oxygen consumption
Natrium
Note: when circulation water fails to meet requirements listed in the table above, please add anti-scale
composition to keep the unit always in normal operation.
Description
Name
Bolt M6X16
Swell Screw M8X60
Relief Valve 1/2
Nut
Gasket
Pipe Hoop φ13
Extruded strip
Fixing strap
)
3
)
3
QTY.
2
Fix the water tank to the wall
4
/
2
/
1
/
1
Connect the water pipe and Water inlet pipe sub-assy
1
Install on the 3way connector
2
Sealing function, see below blue circle
2
/
The drainage pipe using for the relief valve to drainage the
1
water
1
Fix the drainage pipe
Fix the water tank and avoid the damage appearance of the
1
water tank
1
Fix the water tank to the wall
Parametric value
6.8~8.0
< 1
< 50
< 1
< 0.3
< 50
< 30
< 70
< 10
< 300
< 0.5
< 50
Cannot be detected
< 3
< 150
37
Joint pipe thread
1"Male BSP
3/4"Female BSP
3/4"Female BSP
3/4"Female BSP
Function
Unit
/
NTU
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
μs/cm
mg/L
mg/L
mg/L
mg/L
mg/L

Advertisement

Table of Contents
loading

Table of Contents