Connection Of Waterway System - Sinclair STHERM SMH IRB Series Installation Manual

Monoblock inverter air to water heat pump
Table of Contents

Advertisement

Outline (Diameter × H) (mm)
Package (W×D×H) (mm)
Net weight
Gross weight
Description
Hot water outlet of water tank
Circulating water inlet/outlet of water tank
Cooling water inlet of water tank
Pipe joint

16.3 Connection of waterway system

(1) If connection between water tank and indoor unit should be through the wall, drill a hole φ70 for pass of
circulating water pipe. It is unnecessary if the hole is not needed.
(2) Preparation of pipelines: Circulating water outlet/inlet pipe must be hot water pipe, PPR pipe with nominal
out diameter of dn25 and S2.5 series (wall thickness of 4.2mm) being recommended. Cooling water inlet
pipe and hot water outlet pipe of water tank should also be hot water pipe, PPR pipe with nominal out
diameter of dn20 and S2.5 series (wall thickness of 3.4mm) being recommended. If other insulated pipes
are adopted, refer to the above dimensions for out diameter and wall thickness.
(3) Installation of circulating water inlet/outlet pipes: connect the water inlet of the unit with circulating outlet of
water tank and water outlet of unit with circulating inlet of water tank.
(4) Installation of water inlet/outlet pipes of the water tank: safety check valve, filter and cut-off valve must be
installed for the water inlet pipe according to the installation sketch of the unit. At least a cut-off valve is
needed for the water outlet pipe.
(5) Installation of blow-off pipes at the bottom of water tank: connect a piece of PPR pipe with drainage outlet
to floor drain. A cut-off valve must be installed in the middle of the drainage pipe and at the place where it is
easy to be operated by the users.
(6) After connection of all waterway pipelines, perform the leakage test firstly. After that, bind up the water
pipes, water temp sensor and wires with wrapping tapes attached with the unit.
(7) Refer to Installation Sketch of the Unit for details.
Main Unit
Model
K(mm)
kg
kg
Joints Dimension
Power Cord of Booster Heater
Blow-off Outlet
ST-300AF
738×870×1843
Joint pipe thread
3/4"Female BSP
3/4"Female BSP
3/4"Female BSP
3/4"Female BSP
Water Tank
Hot water outlet
Temp Sensor 1
Temp Sensor 2
Safety check
valve
Cooling
water inlet
36
320
Φ620×1725
135
163
Other
Thermal
System
Filter