Advertisement

Quick Links

IPPTZ-EL1MPIR250L20X Installation Manual
Version 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IPPTZ-EL1MPIR250L20X and is the answer not in the manual?

Questions and answers

Summary of Contents for Security Camera King IPPTZ-EL1MPIR250L20X

  • Page 1 IPPTZ-EL1MPIR250L20X Installation Manual Version 1.0...
  • Page 2: Table Of Contents

    Table of Contents IR INTELLIGENT SPEED DOME INSTALLATION ..........1 Installation Preparation ......................... 1 Initial Setup ............................. 1 Dial Switch Setup (For Analog Speed Dome Only)................1 1.3.1 Dial Switch ............................1 1.3.2 Parity Setup ............................2 1.3.3 Baud Rate ............................2 Reset and SD card Installation (For IP Speed dome only) .............
  • Page 3 3.2.1 Installation Requirements ......................10 3.2.2 Installation Steps..........................10 POLE MOUNT BRACKET ................12 Installation............................. 12 4.1.1 Installation Requirements ......................12 4.1.2 Installation Steps..........................12 BRACKET DIMENSIONS ................. 14 Wall Mount Bracket ..........................14 Hanging Mount Bracket (Multiple Lengths) ..................14 Corner Mount Bracket.........................
  • Page 4 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN THE 24V AC CABLE DIAMETER AND THE TRANSMISSION DISTANCE..........19 APPENDIX IV WIRE GAUGE REFERENCE SHEET ........20 10 APPENDIX V SAFETY ROPE INSTALLATION ..........21...
  • Page 5 Welcome Thank you for purchasing our speed dome! Please read the following safeguards and warnings carefully before you install or use the product!
  • Page 6 Important Safeguards and Warnings Safety Measures Qualified Engineer Needed The installation engineer or maintenance engineer shall have corresponding CCTV system installation certificate or maintenance qualification certificate. The installation engineer or maintenance engineer shall have qualification certificate for work at height. The installation engineer or maintenance engineer shall have the basic knowledge and operation technique for low-voltage cable layout and low-voltage electronic cable connection.
  • Page 7 95% knitted copper shield International Model Max Distance (Ft\M) RG59/U 750ft (229m) RG6/U 1,000ft (305m) RG11/U 1,500ft (457m) Please keep all package material well for future use Please keep speed dome package material well in case you need to send it back to your local retailer or manufacturer for maintenance work.
  • Page 8 Do not allow the plastic or rubber material to touch the shell for a long time. It may result in paint flake.
  • Page 9: Ir Intelligent Speed Dome Installation

    1 IR INTELLIGENT SPEED DOME INSTALLATION 1.1 Installation Preparation Basic Requirement All installation and operation here should conform to your local electrical safety codes. Before installation, please open the package and check all the components are included. Please make sure the speed dome installation environment and installation mode can meet your requirement.
  • Page 10: Parity Setup

    1. Address and dial switch button label 2. Protocol dial switch button. 3. Address dial switch button. Figure 1-1 1.3.2 Parity Setup Please refer to the parity setup sheet for detailed information. Parity NONE EVEN NONE 1.3.3 Baud Rate Please refer to the baud rate sheet for detailed information. Baud Rate 9600bps 4800bps...
  • Page 11: Reset And Sd Card Installation (For Ip Speed Dome Only)

    …… ………………………………………………………………… 1.4 Reset and SD Card Installation (For IP Speed dome only) You can see there are a RESET button, dial switch button and Micro-SD card on one side of the PCB of the speed dome. See Figure 1-1 . It is 1 when you set the button as ON.RESET button is to restore factory default setup.
  • Page 12: Speed Dome Installation

    Installation Holes Figure 1-3 1.5.4 Speed Dome Installation Step1: Connect the speed dome to the bracket. Use the quick installation screw of the speed dome and the quick instillation block to fix the speed dome on the bracket. Use the M6 inner hex screw to secure firmly. See Figure 1-4. Bracket Cable M6 Inner Hex Screw...
  • Page 13 Label 1 Label 3 Purple: ALARM_COM POWER Brown: ALARM_OUT Red=AC24V Red: ALARM_IN1 Black=AC24V Orange: ALARM_IN2 Yellow&green=GND Yellow: AUDIO OUT Black: GND Green: AUDIO GND White: AUDIO IN Label 2 Label 4 RS485 Video Out Yellow=A+ Orange=B- Figure 1-5 Step3: Secure the bracket Secure the speed dome and the bracket to the wall firmly.
  • Page 14: Hang Mount Installation

    2 Hang Mount Installation 2.1 Installation Components Please refer to the following sheet for bracket and components information. See Figure 2-1. Straight Pole Hang Mount Bracket Connection Plate (With Cable Exit Slot ) Safety Rope Hole Adapter Block Screw thread Hang Mount Bracket Connection Plate Connection (Without Cable Exit Slot )...
  • Page 15 Fix the connection plate to the ceiling and then turn the connection block to the bracket connection plate. See Figure 2-3. Hang Mount Bracket Connection Plate Adapter Block Figure 2-3 Step 3 Connect cable and the speed dome. Connect the safety rope of the speed dome to the safety rope hole of the adapter block. Now you can connect the cable: video, RS485, power (network, alarm, audio are optional).
  • Page 16 Step 1: Dig holes Draw the installation holes in the wall according to the holes at the bottom of the connection plate. Dig the installation holes. Insert the expansion bolts into the holes. (Please note the expansion bolts are not included in the accessories bag.). See Figure 2-2. Step 2 Components installation Fix the bracket connection plate to the ceiling and then turn the straight pole to the connection plate.
  • Page 17 Safety Rope Quick Installation Port Quick Installation Screw Figure 2-6 Please note, if the speed dome is installed in the outdoor environments, you need to paste enough Teflon tape at the top screw thread of the steeve and then turn the steeve to the flange firmly.
  • Page 18: Corner Mount Bracket

    3 Corner Mount Bracket 3.1 Component Installation Corner mount bracket and its components are shown as below. See Figure 3-1. Figure 3-1 3.2 Installation 3.2.1 Installation Requirements The corner mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments where there is a 90 degrees angle.
  • Page 19 Figure 3-3...
  • Page 20: Pole Mount Bracket

    4 Pole mount bracket Pole mount bracket and its components are shown as below. See Figure 4-1. Figure 4-1 4.1 Installation 4.1.1 Installation Requirements The corner mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
  • Page 21 Figure 4-3...
  • Page 22: Bracket Dimensions

    5 BRACKET DIMENSIONS 5.1 Wall Mount Bracket The wall mount bracket dimensions are shown as below. See Figure 5-1. Figure 5-1 5.2 Hanging Mount Bracket (Multiple Lengths) The hanging mount bracket is shown as below. See Figure 5-2. Figure 5-2...
  • Page 23: Corner Mount Bracket

    5.3 Corner Mount Bracket The corner mount bracket is shown as below. See Figure 5-3. Figure 5-3 5.4 Pole mount bracket The corner mount bracket is shown as below. See Figure 5-4. Figure 5-4...
  • Page 24: Appendix Ⅰ Thunder Proof And Surge Protection

    6 APPENDIX Ⅰ THUNDER PROOF AND SURGE PROTECTION This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 1500W, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to take necessary precaution measures when installing the speed dome in the outdoor environment.
  • Page 25: Appendix Ⅱ About Rs485 Bus

    7 APPENDIX Ⅱ ABOUT RS485 BUS 7.1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 120Ω. Its max load amount is 32 effective loads (including main control device and devices to be charged). 7.2 RS485 Bus Transmission Distance When we take 0.56mm (24AWG) twisted-pair as communication cable, the max transmission distance (theoretically) are listed below (according to different baud rates).
  • Page 26: Rs485 Bus Faq

    Figure 7-2 7.4 RS485 Bus FAQ Phenomenon Possible Reasons Solution Speed dome Host address(baud rate) and Modify host or speed dome setup ; can run self- speed dome address(baud rate) Switch RS485 positive end and diagnosis but I are not match; negative end;...
  • Page 27 8 Appendix Ⅲ The relationship between the 24V AC cable diameter and the transmission distance It is the recommended transmission distance when the cable diameter is fixed and the 24V AC power consumption is below 10%. For the AC device, the max permission voltage power consumption is 10%.
  • Page 28 9 Appendix IV Wire gauge reference sheet Metric bare wire Bare wire cross diameter section (mm) (mm ) 0.050 0.00196 0.060 0.00283 0.070 0.00385 0.080 0.00503 0.090 0.00636 0.100 0.00785 0.110 0.00950 0.130 0.01327 0.140 0.01539 0.160 0.02011 0.180 0.02545 0.200 0.03142 0.230...
  • Page 29 10 Appendix V Safety Rope Installation Remove one M4 screw from the speed dome and then use the M4 screw of the safety rope to fix the safety rope on the speed dome. Please note the contents in this chapter are for hang (pendant) mount installation only. Safety Rope Speed Dome M4 Screw M4 Screw of the...

Table of Contents