Selection of connectable accessories.
The accessory works only in Auto mode.
WITHOUT
Select this when not using an accessory.
TURN 1
1: Sensor type (PNP is the standard for the sensors
supplied by us)
2: Delay drip (Pause after filling, before
restarting the turntable)
3: Stop delay (Pause after stopping of the
turntable, before filling)
Activation for the connection of Ø 65 cm turntable (Art. 303017).
Functioning according to the above activation of the turntable
(turntable is switched on only in Auto mode):
- press the
key in the AUTO menu to start the turntable
- turntable rotates until the sensor detects a jar
- turntable stops, the time of the stop delay runs out
- machine fills the jar with the set quantity
- the time of drip delay runs out
- turntable starts again until the next jar is detected
- turntable stops automatically after one minute of idle running.
In a few cases TURN 2 is selected for Ø 65 cm turntable (see turntable
instructions).
TURN 2
Activation for the connection of Ø 100 turntable (Art. 303038 or
303039).
The setting is made the same way as for TURN 1. Additionally,
here the speed of the turntable can be set in % in the top line.
Here, a factory reset can be performed to reset the software to its
factory settings in the event of malfunctions. Individual settings (e.g.
entered nominal filling quantities) are thereby erased.
COUNTER
This counter measures the total quantity filled/pumped by the device in
liters. The recorded value is not resettable and can be compared with the
records of an operating hour counter. The indicated value is only an
approximate value because the different calibrations are not included in
the calculation.
per day COUNTER
Batch counter (quantity in liters), resettable. Press
package
Jar counter (number of pieces), resettable. Press
Operation
37
to reset.
to reset.