External Switches; Microswitch; Foot Switch - Nassenheider Fill Up 2 Manual

Table of Contents

Advertisement

7.7

External switches

7.7.1

Microswitch

Fig. 20: Microswitch (Art.
The microswitch is to be adjusted at the Y-bracket so that it triggers the filling
process when the jar is pressed. It is active only in Auto mode. The key
be used instead of the microswitch. The key is due to increased wear not suitable for
continous operation.
We recommend the microswitch only for filling jars with an opening Ø from 30 mm.
To avoid accidental triggering of the filling process, the microswitch should be
connected only when all preparations for the filling (priming and calibration) are
completed.
7.7.2

Foot switch

Optionally available as accesory.
Fig. 21: Foot switch
The foot switch is connected parallel to the key
modes, and has therefore exactly the same functionality. The key is due to increased
wear not suitable for continous operation.
It is suitable for filling all jar types.
To avoid any accidental triggering of the filling process, the foot switch should be
connected only when all preparations for the filling (priming and calibration) are
completed.
307039)
(Art. 303029)
Putting into operation
of the keypad in all operating
23