E4
OVER CURRENT PROTECTION
If E4 error is reported continuously, it
is considered to be hardware fault of
controller.
Solution 1:
Check whether the brake handle wire
is connected properly.
Solution 2:
Replace brake handle to test, if the
error code goes away the handle was
the issue.
Solution 3:
Replace the handlebar assembly to
test, if the error code goes away the
display was the issue.
E7
MOTOR SENSOR ERROR
If E7 is reported this means that a
faulty motor
sensor is present.
Solution:
Replace the motor to test, if the error
goes away
the motor was the issue.
E5
UNDER VOLTAGE PROTECTION
If E5 is reported continuously, check
whether
the battery voltage is too low (Below
30 Volts).
Solution:
Replace with a new battery to test, if
the error goes away the battery was
E8
MOTOR PHASE LOSS
If E8 is reported this means that one
or more phase connectors are not
properly connected or properly
working.
Solution 1:
Check if the phase wires are properly
connected.
Solution 2:
Replace the controller to test, if the
error goes away the controller was
the issue.
Solution 3:
Replace the motor to test, if the error
goes away the motor was the issue.
21
E6
OVER VOLTAGE PROTECTION
If E6 is reported the battery voltage is too
high.
Solution:
The battery voltage is too high, avoid
sudden braking, rushing actions and it will
return to normal when part of the power has
been used up.
E9
CONTROLLER ERROR
If E9 is reported continuously, this means
that the controller is faulty.
Solution:
Replace the controller to test, if the error
goes away the controller was the issue.