Ecler VIDA-24Q User Manual
Hide thumbs Also See for VIDA-24Q:

Advertisement

Quick Links

VIDA-24Q
AMPLIFIERS
Digital Amplifiers
USER MANUAL
50-0429-0100
VIDA-24Q
EN

Advertisement

Table of Contents
loading

Summary of Contents for Ecler VIDA-24Q

  • Page 1 VIDA-24Q AMPLIFIERS Digital Amplifiers USER MANUAL 50-0429-0100 VIDA-24Q...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PRECAUTIONS ........................3 1.1 Important Remark ..........................3 1.2 Important Safety Instructions ......................4 1.3 Cleaning ..............................4 PACKAGE CONTENTS ......................5 FEATURES ..........................5 3.1 Main Features ............................6 INSTALL & CONNECT ......................6 4.1 Location, Assembly and Ventilation ....................7 4.2 Mains Connection ..........................
  • Page 3: Precautions

    1. PRECAUTIONS 1.1 IMPORTANT REMARK The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
  • Page 4: Important Safety Instructions

    1.2 IMPORTANT SAFETY INSTRUCTIONS Read these instructions. 12. Unplug the device during lightening sorts or when unused for long periods Keep these instructions. of time. Heed all warnings. Refer servicing qualified Follow all instructions. personnel. Servicing is required when Do not use this device near water. the device has been damaged in any Clean only with dry cloth.
  • Page 5: Package Contents

    4. Desktop feet, rack 19" installation hardware. 5. Guarantee Card. 3. FEATURES VIDA-24Q is a 2400W digital amplifier, with 4 amplified outputs that can be independently configured in high (100/70V) or low (8/4/2ohm) impedance. The VersaPower technology, developed by Ecler, allows an asymmetrical power distribution, and thanks to the Smart VersaPower tool it helps installers by facilitating a smart and fast configuration.
  • Page 6: Main Features

    • Control and scheduled slot audio player. events for automation. VersaPower is the amplification technology, developed by Ecler, that allows asymmetrical power distribution among amplified outputs, independent of load. Smart Versapower is the tool that allows automatic gain and sensitivity adjustment, to distribute in an easy and quick way, the total power among the amplified outputs.
  • Page 7: Location, Assembly And Ventilation

    4.1 LOCATION, ASSEMBLY AND VENTILATION Vida series devices have a 19" rack format (2RU). It is very important not to enclose the amplifier or expose it to extreme temperatures as it generates heat. It is also necessary to promote the passage of fresh air through the ventilation holes of the chassis.
  • Page 8: Analogue Input Connections

    Please refer to the web application manual for more information on www.ecler.com Signal input connectors are 3 position screw terminal block. The wiring is: Vivo o señal directa >...
  • Page 9: Digital Audio Inputs And Outputs

    4.5 DIGITAL AUDIO INPUTS AND OUTPUTS VIDA allows the reception of 4 channels of digital audio DANTE™ and the sending of 4 channels of digital audio DANTE™ through an Ethernet network compatible with the transport of digital audio over IP through the DANTE™ protocol. The routing of the digital audio signals DANTE™...
  • Page 10: Operation Example

    VIDA embedded web application. Please refer to the web application manual for more information on www.ecler.com Signal input connectors are 3 position screw terminal block. The wiring is: Vivo o señal directa >...
  • Page 11: Gpi Ports

    Ground connections of all devices those ports belong to must be joined. • The connection cables can be up to 500m long if a section of 0.5mm2 is used. • Consult the available accessories at your ECLER dealer at www.ecler.com...
  • Page 12: Gpo Ports

    4.9 GPO PORTS VIDA has on its rear panel 4 relay outputs NO / NC (normally open / normally closed). Each of these outputs can have its status change associated with a user preset by means of a specific function programmed through VIDA web application, such as a calendar event or the touch of a key available on a user panel.
  • Page 13: Ethernet Ports

    4.11 ETHERNET PORTS The RJ-45-type ETHERNET connectors on the rear panel, named NET1 and NET2, allows the equipment to be connected to an Ethernet network, or directly to a computer or other device with an Ethernet interface, point-to-point. This connection enables, within a local network, the following: •...
  • Page 14 Net1 Control + Dante™ Redundancy, Net2 Dante™ Primary: Net1 incorporates Dante™ redundancy. Recommended when using Dante™ with redundancy in two isolated LANs. Switch Mode: ethernet ports perform as a 2-port switch and support control + Dante™ Primary traffic for the amplifier. The behaviour of the two Ethernet ports in the rear panel is configured via VIDA web application.
  • Page 15: Redundant Mode

    4.11.1 REDUNDANT MODE There are two simultaneous network connections (each with its own IP address, both different) so that the information Ethernet packets Dante™ are transmitted via both connections. Each port (primary and secondary) must be connected to a different physical Ethernet local network, or to a different virtual local network (VLAN), correctly configured and isolated from each other.
  • Page 16: Switch Mode

    4.11.2 SWITCH MODE In this mode, only a single network connection is actually enabled (and therefore only one IP address exists), with the primary and secondary ports behaving as ports of a network switch integrated within VIDA, to which devices forming part of the system's Dante™...
  • Page 17: Panel Functions

    6. PANEL FUNCTIONS 6.1 FRONT PANEL Control knobs, KNOB1-4 Limit indicator LED On/Sleep Button Thermal indicator LED Signal indicator LED Dante indicator LED Clip indicator LED Data indicator LED Protection indicator LED On/Sleep indicator LED Standby/mute indicator LED 6.2 REAR PANEL Power switch GPO ports, GPO1-4 Mains socket base...
  • Page 18: Technical Data

    7. TECHNICAL DATA 7.1 TECHNICAL SPECIFICATIONS VIDA-24Q INPUTS Number of Inputs 4 analogue input channels 4 DANTE™ Network Rx channels 1 embedded player, 1 embedded signal generator Analogue input connection type IN1-4: 3-pin Euroblock, balanced, pitch 3,5 mm. Digital input connection type Ethernet, managed via Dante™...
  • Page 19 SIGNAL Voltage gain 28 to 40 dBV 30,2 to 42,2 dBu Input sensitivity -6 to +6 dBV -3,78 to 8,2 dBu 0,5 to 2 Vrms Input impedance >24k Max input level +18 dBV +20,2 dBu Frequency response 15Hz-25kHz THD + Noise <...
  • Page 20 1/8 POWER, @ 4Ω Power 483 W | 493 VA Current Draw 4,16 Arms Thermal Loss 115,2kcal/h | 457,3BTU/h IDLE Power 68 W | 89 VA Current Draw 0,75 Arms Thermal Loss 58,5kcal/h | 232,1BTU/h SLEEP MODE Power 3,6 W | 10,2 VA Current Draw 0,09 Arms Thermal Loss...
  • Page 21 MONITORING Signal Present SP LED (White) per channel Clipping CLIP LED (Red) per channel Protect PROT LED (Red) per channel Standby / Mute STBY/MUTE LED (White) per channel Limit LIMIT LED (Red) per unit Thermal THERMAL LED (Red) per unit Dante™...
  • Page 22: Mechanical Diagram

    PHYSICAL Operating temperature -10º to 50º C 14º to 122º F Operating humidity 5 - 85% RH, non-condensing Storage temperature -10º to 50º C 14º to 122º F Storage humidity 5 - 85% RH, non-condensing Installation options Rack 19" installation & desktop Included accessories Universal Main cords, Euroblock Connectors (inputs /outputs), Desktop feet, rack 19"...
  • Page 24 NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications. For technical queries contact your supplier, distributor or complete the contact form on our website, Support / Technical requests. Motors, 166‐168 -08038 Barcelona ‐ Spain‐(+34) 932238403 information@ecler.com www.ecler.com...

Table of Contents