GE MDS entraNET Series Startup Manual page 23

900 mhz and 2400 mhz extended range ip networking transceivers
Table of Contents

Advertisement

Table 4. Troubleshooting With LEDs (Continued)
Symptom
LAN/ETH LED does
not turn on.
COM1 or COM2 LED
does not show traffic.
Table 5
below shows the proper type of Ethernet cable to use with the
radio when connecting to external devices.
Table 5. Proper Ethernet Cable Type
Radio Type
AP
AP
Remote
Remote
05-4565A01, Rev. A
Possible Cause and Resolution
a. Verify that the Ethernet cable is connected at both
ends.
b. Verify that the proper type of Ethernet cable
(straight-through or crossover) is used. See
5
below for the proper cable type.
Check the configuration of COM port and the remote
serial gateway settings.
Connected Device
Hub or network switch
PC
PC
Hub or network switch
MDS entraNET Start-Up Guide
Cable Type Required
Straight-through
Crossover
Straight-through
Select for the external
device port
Table
19

Advertisement

Table of Contents
loading

Table of Contents