The "r" will automatically appear during the auto calibration process when the console has
determined that a radar is being used. When manually entering a radar calibration number
the "r" must be turned on by pushing the Clr key. With this key you can toggle between radar
or wheel sensor. The calibrationvalue itself is adjusted with the Up and Down keys.
The auto calibration procedure can be escaped with the Pro or Clr keys. The console will then
return to the previous calibration value..
Note: The auto speed calibration should be repeated at least twice and an average of
the calibration numbers should be entered.

Simulated Speed

If you enter 0 in this programming step, then the Console always shows a simulated speed of
6 mph. This can be used to test out the sprayer at stand still. The simulated speed feature
allows you to check out the sprayer at a certain speed without actually moving the sprayer.
This can be done prior to any spraying activity.
P
Depress the
key to accept the flow meter value and advance to the next program step.
RO
F
M
C
LOW
ETER
Default = 650 pulses/liter
First, locate the factory calibrated Flow Meter pulse rate tag on the Flow Meter. If this varies
from the default value of the console, use the Up and Down keys to modify the value.
Note: The Flow Meter Calibration number will always be expressed in pulses/l. The
monitor will automatically make the necessary conversion if operating in US units.
Depress the P
key to accept the flow meter value and advance to the next program step.
RO
S
W
ECTION
I DT H
Default = 10 ft (3.00 m)
In the next 9 programming steps the width of each section has to be entered. If a certain
section is not used then the value must be programmed to zero (i.e. If your sprayer only has 3
sections, only program values for the first 3 sections. All others should be set to 0).
Use the Up and Down keys to change the value.
TeeJet 814 Sprayer Monitor
>r12.4puls/300ft
ALI BRAT I ON
> 650 puls/l
> 10.0ft
Programming and Operating Manual (V1.00)
Sect 1
Page 7 of 15