Ope Ra T Ing I Nst Ruc T Ions; Sprayer Checkout; The Spraying Operation - TeeJet 814 Programming And Operating Manual

Sprayer monitor
Table of Contents

Advertisement

Ope ra t ing I nst ruc t ions

S
C
PRAYER
HECKOUT
Before spraying check all connections related to the Sprayer Control assembly. Particular
attention should be given to the speed sensor to be sure the sensor and bolts or magnets are
in-line, and properly secured.
Very important: Whenever you are working around a sprayer or farm chemicals, be
Partially fill the sprayer tank with water to flush the system and to make a visual check of the
spray tips to be sure all tips are delivering a good spray pattern.
Follow these steps, in sequence, being sure the Master Switch is in its "OFF" position:
*
Be sure the tank shut-off valve is open.
*
Start the engine, engage pump, and set the rpm to that which will be used when spraying.
*
Switch the computer on by depressing the Pro key on the display panel.
*
Turn "ON" the toggle switches for each of the spray booms on your sprayer.
*
Now, toggle the Master switch to "on."
*
Adjust the pressure with the +/- switch.
At this point, the sprayer will be activated and spray tip performance can be visually checked.
The +/- switch can be used to raise or lower your spraying pressure. To stop spraying, toggle
the Master switch to "OFF".
The above steps provide a quick way to check-out your sprayer and computerized monitor
system.
T
S
HE
PRAY I N G
You have filled the sprayer tank and have thoroughly mixed the chemical(s). Your application
rate has been determined as well as the spray tip you will be using, with the sprayer data
programmed into the computer.
*
Switch the computer on by depressing the Pro key on the display panel.
*
Toggle the boom switches to their "ON" position, for each of the booms on your sprayer.
*
Take note of the "numbered" booms on each side of the sprayer, so that the appropriate
boom can be toggled "OFF" as necessary.
*
While spraying with the Master switch "ON", you can scroll through the different displays
until the information you want is on the display :
♦ actual application rate in GPA (l/Ha)
♦ vehicle speed in MPH (Km/h)
♦ pressure in PSI (bar)
♦ actual working width in ft (m)
♦ application area covered in Ac (Ha)
TeeJet 814 Sprayer Monitor
sure to wear protective clothing and eyewear.
O
PERAT I ON
Programming and Operating Manual (V1.00)
Page 12 of 15

Advertisement

Table of Contents
loading

Table of Contents