OPTIMOD-FM DIGITAL
Current: 30 mA maximum
Indications: Tally outputs can be programmed to indicate a number of different operational
and fault conditions, including Input: Analog, Input: Digital, Analog Input Silent, AES In-
put Silent, and AES Input Error.
Voltage: 85–264 VAC, 50–60 Hz, 30 VA.
Connector: IEC, EMI-suppressed. Detachable 3-wire power cord supplied.
Fuse: 2.5A 20mm Quick Acting HBC, mounted on the power supply circuit board.
Grounding: In order to meet EMI standards, circuit ground is hard-wired to chassis ground.
Safety Standards: ETL listed to UL standards, CE marked.
Operating Temperature: 32 to 122 F / 0 to 50 C for all operating voltage ranges.
Humidity: 0–95% RH, non-condensing.
Dimensions (W x H x D): 19‖ x 1.75‖ x 14.25‖ / 48.3 cm x 4.5 cm x 36.2 cm. One rack unit
high.
Humidity: 0–95% RH, non-condensing.
RFI/EMI: Tested according to Cenelec procedures. FCC Part 15 Class A device.
Shipping Weight: 10 lbs / 4.6 kg
Five Years, Parts and Service: Subject to the limitations set forth in Orban's Standard
Warranty Agreement.
Because engineering improvements are ongoing, specifications are subject to change with-
out notice.