Multi-Function Burner Display
Burner control
20107665
20167984
20179829
Code
MFBD 4.3" TOUCHSCREEN KIT - LMV3
MFBD 4.3" TOUCHSCREEN KIT - LMV5
MFBD 7" TOUCHSCREEN KIT - LMV5
Model
0214190 - 01/2022

Advertisement

Table of Contents
loading

Summary of Contents for Riello LMV3

  • Page 1 Installation, use and instructions Installation, use and instructions Multi-Function Burner Display Burner control Code Model 20107665 MFBD 4.3" TOUCHSCREEN KIT - LMV3 20167984 MFBD 4.3" TOUCHSCREEN KIT - LMV5 20179829 MFBD 7" TOUCHSCREEN KIT - LMV5 0214190 - 01/2022...
  • Page 2: Table Of Contents

    4.3" Touch Screen Kit (Lmv3) - 20107665 ........
  • Page 3 Index Setting Up Control Mode Setting Up Solo Mode ..............22 Setting Up Piccolo Mode .
  • Page 4: Information And General Warnings

    Information and general warnings Information and general warnings General warnings Disconnect all power supplies before attempting installation Installation must only be conducted by qualified and Installation must only be conducted by qualified and skilled personnel in compliance with these instruc- skilled personnel in compliance with these instruc- tions and all local and national codes tions and all local and national codes...
  • Page 5: System And Hardware Configuration

    System and hardware configuration Introduction The Multi-Function Burner Display is included in kits de- fined in section 2.2 that can selected as 4.3" or 7" displays with LMV3 and LMV5 controls. Burner touch screen kits BOM 2.2.1 4.3" touch screen kit (LMV3) - 20107665 4.3" kit (20107665) Components list...
  • Page 6: 7" Touch Screen Kit (Lmv5) - 201798294

    Massimo Solo System and hardware configuration Piccolo 2.2.3 7" touch screen kit (LMV5) - 20179829 7" kit (20179829) Components list Description Part Number DB9 to wire 20143749 7" touch screen 20164159 Wire (beldon,white, red , green, black) 120AC/24 VDC power 20138550 supply Din rail C5311121 OCI412.10 C5360140 Light and Light button M6 Threaded rivet...
  • Page 7: Factory Integrated Components

    System and hardware configuration Factory integrated components Burner integration kit installed and tested. ► 4.3” HMI (LMV3/LMV5) ► 7.0” HMI (LMV5) Protocol gateway (optional) 2.4 Standard features In order to handle a wide variety of systems, the touch- Pumps setup ► Boiler circulator pump off delay screen is configurable. Please note that most of these...
  • Page 8: Communication

    (Massimo option). For remote connection to Massimo, see Massimo manual. For remote connection to Massimo, see Massimo manual. The burner touchscreen utilizes Modbus RTU, RS485 for communications to the burner controls including LMV3, temperature controller. 2.5.2 External communication Points list is protocol dependant, consult section 6.
  • Page 9: Massimo System Overview

    System and hardware configuration 2.6.3 Massimo system overview Massimo Burner 1 Burner 2 Burner 3 Burner 4 Supply Belly Belly Supply Belly Supply Belly Supply Temp./ Temp. Temp. Temp./ Temp. Temp./ Temp./ Temp. Pressure Pressure Pressure Pressure Return Return Return Return Temp.
  • Page 10: Navigation

    System and hardware configuration Navigation BURNER Lead/Lag Info (Piccolo Configuration) INFO ERROR HISTORY LEAD/LAG LEAD/LAG LEAD/LAG LEAD/LAG CONFIG 2 CONFIG 3 CONFIG 4 CONFIG 1 ALARM & SYSTEM WARNINGS OVERVIEW PICCO- LO MODE LEAD/LAG CONTROL PAGE Main Menu MEDIA/ COMMS DISPLAY NIGHT STANDBY CONFIG CONFIG.
  • Page 11: Solo Wiring: Lmv3X, 4.3" Touchscreen

    System and hardware configuration Navigation 2.7.1 Solo wiring: LMV3x, 4.3" touchscreen Please note: Use the wiring diagrams as reference only. 2.7.2 Solo wiring: LMV5x, 4.3"/ 7" touchscreen Please note: Use the wiring diagrams as reference only. 0214190 - 01/2022...
  • Page 12: Piccolo Wiring: Lmv3X, 4.3" Touchscreen

    System and hardware configuration 2.7.3 Piccolo wiring: LMV3x, 4.3" touchscreen Please note: Use the wiring diagrams as reference only. 2.7.3 Piccolo wiring: LMV5x, 4.3"/7" touchscreen Please note: Use the wiring diagrams as reference only. 0214190 - 01/2022...
  • Page 13: Massimo Wiring: Lmv5X, 4.3" Touchscreen

    2.7.4 Massimo wiring: LMV5x, 4.3" touchscreen 2.7.5 Massimo wiring: LMV5x, 7" touchscreen 0214190 - 01/2022...
  • Page 14: User Interface

    Refer to 3.3 Refer to 3.4 Refer to 3.16 Local/remote setpoint available. Local setpoints include: LMV3/LMV5 flamesafeguard selection ► Switch for selectable setpoint source (local/remote) ► Outside Reset Setpoint Control mode selection: ("Manual On", "Manual Off", "Re- mote Modulation", "Solo", "Picollo", "Massimo") Remote setpoints include: ►...
  • Page 15: Burner Mode

    Massimo Solo User interface Piccolo Burner Mode Standalone (Solo): The burner will use local or remote Remote Modulation: The burner will run at the specified setpoint to modulate and maintain the process value (PV), load received from the BMS system. Load requests from the without any external intervention.
  • Page 16: Media/ Units Selection

    Massimo Solo User interface Piccolo Media/ Units selection 3.6 Inputs info and configuration When using Burner with LMV3 and RWF55 Help screens are available to assist the technican properly set up the RWF55 to work with the touchscreen. 0214190 - 01/2022...
  • Page 17: Remote Setpoint Source & Remote Modulation Source

    Massimo Solo User interface Remote Piccolo Modulation Remote Setpoint Source & Remote Modulation Source Refer to 3.6 Refer to 3.6 A remote modulation signal can be sent to the burner via A remote setpoint can be sent to the burner via 0-20ma/4- 0-20ma/4-20ma/0-10vd hardwired or bus signal.
  • Page 18: Pump/Valve Configuration

    Massimo Solo User interface Piccolo 3.9 Pump/Valve Configuration 3.10 Night Setback Night setback can be set for any range of time, any day of the week and for any range of time. Night setback setpoint will take priority over local or remote setpoint. 0214190 - 01/2022...
  • Page 19: Ethernet Configuration

    ►Massimo mode: Select "Massimo IP config", in next page select boiler number. Power cycle after selection 3.12 Comms Config If a Riello gateway is connected to the Riello burner, it is configured in "BMS communication". The S3 dip switch has to be in the off position Available gateway protocols: ►...
  • Page 20: General Setup Guide

    Massimo Solo User interface Piccolo 3.13 General setup Guide The "General setup Guide" offers assistance to the user in setting up the touchscreen. 3.14 System setup examples The "Setup system examples" gives an overview view of the control flow for the MFBD Examples are included as a guide to setting up RWF55 0214190 - 01/2022...
  • Page 21: Alarms & Warnings Page

    Massimo Solo User interface Piccolo 3.15 Alarms & Warnings page Error screens gives the user plenty of information about each error occuring at the burner, including what the burner failure is, when it occured and also a translation of what the error means.
  • Page 22: Burner

    Massimo Solo User interface Piccolo 3.16 Burner 0214190 - 01/2022...
  • Page 23: Setting Up Control Mode

    Setting up control mode 4.1 Setting up Solo mode See section 3 for Solo mode functionality. See below for putting touch screen in Solo mode. Set for LMV3/5 Select "Standalone (Solo)" After completion your main screen will display "Custom IP selected" 4.2 Setting up Piccolo mode See below for lead/lag functionality.
  • Page 24: Step 2: Selecting Boiler Number

    Setting up control mode Step 2: Selecting boiler number Select "Piccolo IP config" After selecting boiler number, recy- After recycling, on the main screen cle power on the burner. THIS IS you will see "Piccolo BOILER x" VERY IMPORTANT! displayed Step 3: Piccolo configurations The page provides the user with an overall readout of Piccolo setup.
  • Page 25: Step 4: Setting Up Other Burner

    Setting up control mode This screen is for setting up the setpoint shift on the Piccolo system. "Minimum" and "Maximum" BOILER operation SETPOINT is the minimum and maximum setpoint shift per "Boiler SP correction interval in minutes" Hysteresis set the minimum and maximum limits that the setpoint can be shifted to.
  • Page 26: Setting Up Massimo Mode

    Massimo mode. See below for putting touch screen in Massimo mode. Step 1: Selecting Massimo mode Select "Lead/lag Massimo (2+ Set for LMV3/5 boilers)" Step 2: Selecting boiler number Select "Massimo IP config" After selecting boiler number, recy- After recycling, on the main screen cle power on the burner.
  • Page 27: Remote Monitoring - Vnc Viewer

    LAN2 Audio Setting up VNC Viewer application Connect to the Riello touchscreen through a third party VNC software by entering the IP of the touchscreen. The IP of the burner touchscreens is set up and accessed through the burner touchscreen in "Ethernet Configuration"...
  • Page 28: Multi-Function Display Version Update

    Multi-function display version update Introduction The multi-function display is designed and programmed inhouse.Continuous mprovments to are being made to the system. For latest version please request from Riello for newest version (if available). Unpacking the software Unzip "vX.XX_loader" into a separate folder you desire This is the content of the folder "burner hmi"...
  • Page 29 Massimo version update Wait for full boot up, Power OFF the screen and unplug the USB stick. Power screen back on and ..you're done!...:) Select "MISC." (miscellaneous) Answer yes and wait until the screen asks you: "Continue to Update FW?" Answer yes and wait until screen displays: "FW File Burn Success!!"...
  • Page 30: Points List

    Points list Points list Panel points list: Modbus RTU Modbus TCP Point Name Data type 1001 1201 1401 1601 1801 2001 2201 2401 B(X)_Phase Holding Reg. 1002 1202 1402 1602 1802 2002 2202 2402 B(X)_Fuel act. Holding Reg. 1005 1205 1405 1605 1805...
  • Page 31: Gateway Point List: Bacnet Ms/Tp, Bacnet/Ip, Modbus Tcp, Metasys N2, Ethernet/Ip, Lonworks

    Gateway Points list Gateway point list: BACnet MS/TP, BACnet/IP, Modbus TCP, Metasys N2, Ethernet/IP, Lonworks BAC- LON fun., Modbus Unit/ Metasys N2 Data Point Name type,Option, Att., TCP Data SNVT_ Type units Class type Type ject Ana_Input/Integer Holding B(x)_Phase NVUI,-,- No-units (B5-B8) Reg.
  • Page 32 Gateway Points list Modbus TCP/ Unit/ LON fun., type,Op- Metasys N2 Data Point Name Att., BACnet data SNVT_ tion, units Type Class type Type Ana_Input/Inte- Holding Reg 1001 1201 1401 B(x)_Phase NVUI,-,- No-units ger (B5-B8) Ana_Input/Inte- Holding Reg 1002 1202 1402 B(x)_Fuel act.
  • Page 33 Gateway Points list System System information Holding B1_Setpoint Ana_Input Holding Reg. No-units Reg /AV Holding B1_Firing Rate Ana_Input Holding Reg. No-units Reg /AI Holding B2_Setpoint Ana_Input Holding Reg. No-units Reg /AI Holding B2_Firing Rate Ana_Input Holding Reg. No-units Reg /AI Holding 0 - closed, 1 - B3_Setpoint...
  • Page 34 0214190 - 01/2022...
  • Page 35 0214190 - 01/2022...
  • Page 36 0214190 - 01/2022...