7.2

Gateway point list: BACnet MS/TP, BACnet/IP, Modbus TCP, Metasys N2, Ethernet/IP, Lonworks

B1
B2
1
201
2
202
5
205
9
209
10
210
11
211
14
214
26
226
27
227
29
229
1
41
2
42
3
43
4
44
5
45
6
46
7
47
8
48
57,58
257,258
59,60
259,260
71,72
271,272
73,74
273,274
75,76
275,276
85
285
9
49
10
50
88
288
0214190 - 01/2022
Gateway Points list
B3
B4
Point Name
401
601
B(x)_Phase
402
602
B(x)_Fuel act.
405
605
B(x)_Air act.
409
609
B(x)_VSD
410
610
B(x)_Current Fuel
411
611
B(x)_Firing Rate
414
614
B(x)_Flame Signal
426
626
B(x)_Error Code
427
627
B(x)_Diag Code
429
629
B(x)_Error Phase
71
101
B(x)_Call for heat
72
102
B(x)_Safety Loop
B(x)_Gas
73
103
Switches
74
104
B(x)_Air Pressure
75
105
B(x)_Alarm
B(x)_Ign. Trans-
76
106
former
77
107
B(x)_Burner Fan
78
108
B(x)_Fuel Valve
B(x)_Hours Run
457,458
657,658
Gas
B(x)_Hours Run
459,460
659,660
Oil
471,472
671,672
B(x)_Starts Gas
473,474
673,674
B(x)_Starts Oil
475,476
675,676
B(x)_Total Starts
485
685
B(x)_Boiler PV
79
109
B(x)_Blr HL
80
110
B(x)_Blr LWCO
488
688
B(x)_Header PV
LON fun.,
EIP
Metasys N2 Data
type,Option,
Att.,
Type
units
Class
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
NVUI,switch,val-
Ana_Input/Integer
3,4
ue, raw
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
NVUI,switch,val-
Ana_Input/Integer
3,4
ue, raw
(B5-B8)
NVUI,switch,val-
Ana_Input/Integer
3,4
ue, raw
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
NVUI,switch,val-
3,4
Dig_Input
ue, raw
NVUI,switch,val-
3,4
Dig_Input
ue, raw
NVUI,switch,val-
3,4
Dig_Input
ue, raw
NVUI,switch,val-
3,4
Dig_Input
ue, raw
NVUI,switch,val-
3,4
Dig_Output
ue, raw
NVUI,switch,val-
3,4
Dig_Output
ue, raw
NVUI,switch,val-
3,4
Dig_Output
ue, raw
NVUI,switch,val-
3,4
Dig_Output
ue, raw
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
Ana_Input/Integer
NVUI,-,-
3,4
(B5-B8)
NVUI,switch,val-
3,4
Dig_Input
ue, raw
NVUI,switch,val-
3,4
Dig_Input
ue, raw
NVUI,switch,val-
3,4
Dig_Input
ue, raw
30
BAC-
Modbus
Unit/
net
TCP Data
SNVT_
Ob-
type
Type
ject
Holding
AI
No-units
Reg.
De-
Holding
AI
grees-an-
Reg.
gular
De-
Holding
AI
grees-an-
Reg.
gular
Holding
AI
Percent
Reg.
Holding
AI
No-units
Reg.
Holding
AI
Percent
Reg.
Holding
AI
Percent
Reg.
Holding
AI
No-units
Reg.
Holding
AI
No-units
Reg.
Holding
AI
No-units
Reg.
0 - off,
DI
BI
1 - on
0 - open,
DI
BI
1 - closed
0 -
DI
BI
closed,
1 - open
0 - off,
DI
BI
1 - on
0 -
DO
BO
Normal, 1
- Alarm
0 - off,
DO
BO
1 - on
0 - off,
DO
BO
1 - on
0 - off,
DO
BO
1 - on
Holding
AI
Hours
Reg.
Discrete_
AI
Hours
Input
Discrete_
AI
No-units
Input
Holding
AI
No-units
Reg.
Holding
AI
No-units
Reg.
Holding
AI
No Unit
Reg.
DI
BI
No-units
DI
BI
No-units
Holding
AI
No-units
Reg.