Use the following bolt installation procedure:
1. Carbon steel bolts do not require lubrication. Stainless steel bolts are factory-coated
with a lubricant to ease installation. Do not apply any additional lubricant when
installing either type of bolt.
2. Finger-tighten the bolts.
3. Torque the bolts to the initial torque value using a crossing pattern. See
initial torque value.
4. Torque the bolts to the final torque value using the same crossing pattern. See
for final torque value.
5. Verify that the flange bolts protrude through the sensor module before applying
pressure.
Table 2: Torque Values for the Flange and Flange Adapter Bolts
Bolt
Head markings
material
Carbon
Steel (CS)
Stainless
Steel (SST)
Proper Bolt Installation
1
Bolt
2
Sensor module
Emerson FB1200 Flow Computer Quick Start Guide
D301786X012
June 2018
Table 2
Initial torque
Final torque
300 in. -lbs.
650 in. -lbs.
(33.9 N m)
(73.4 N m)
150 in. -lbs.
300 in. -lbs.
(16.9 N m)
(33.9 N m)
for
Table 2
7