"Auto Provisioning" Procedure
Parameter
TELEVENTPAYLOAD
DISABLE_CAL_
WAITING
DISABLE_
CONFERENCE
CALL_FORWARD_
TIMER
DISABLE_ATTENDED_
TRANSFER
LINE1PRIVACY
LINE1_DND_FLAG
AUTOUPDATE
ROUTINEUPGRADE
AUTOUPGRADEHOUR
AUTOUPGRADEMIN
TIMESPAN
FWLEVEL
UPD_FILENAME
28
Description
Payload value
Deactivate
call waiting
Deactivate the
conference function
Timer for call forwarding
Deactivate blind transfer/
attended transfer remains
active
Privacy setting for SIP data
packet transfer (RFC3323)
Activate
do-not-disturb
Activate
Auto Provisioning
Activate
timer for
Auto Provisioning
Hour setting for
scheduled
Auto Provisioning
Minute setting for
scheduled
Auto Provisioning
Timeslot for
updating
multiple devices
Name of
new firmware
Exact name of
the firmware file
A complete overview of the parameters available for the configura-
tion files can be found on
Syntax
numerical
TELEVENTPAYLOAD 97
YES/NO
DISABLE_CALL_WAITING NO
YES/NO
DISABLE_CONFERENCE NO
1~9999
CALL_FORWARD_TIMER 12
YES/NO
DISABLE_ATTENDED_
TRANSFER NO
LINE1PRIVACY 255
YES/NO
LINE1_DND_FLAG NO
ENABLE/
AUTOUPDATE DISABLE
DISABLE
ENABLE/
ROUTINEUPGRADE DISABLE
DISABLE
00~23
AUTOUPGRADEHOUR 01
00~ 60
AUTOUPGRADEMIN 30
0~255
TIMESPAN 60
max. 6 digits
FWLEVEL 1.22
max. 32
UPD_FILENAME
characters
OP150S_v122.img
.
page 60