BANDELIN SONOREX TECHNIK LG Series User Instructions

BANDELIN SONOREX TECHNIK LG Series User Instructions

High-performance ultrasonic generator

Advertisement

Quick Links

User instructions
3 4
High-performance ultrasonic generator series LG
for the operation of ultrasonic cleaning tanks (TM),
ultrasonic immersible transducers, ultrasonic fl at transducer plates,
and reactors
Valid for:
Tabletop housing
Industrial housing
Industrial housing
23366b GB/2019-07
LG .... T /PRO
LG .... F /PRO
LG .... D /PRO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SONOREX TECHNIK LG Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BANDELIN SONOREX TECHNIK LG Series

  • Page 1 User instructions High-performance ultrasonic generator series LG for the operation of ultrasonic cleaning tanks (TM), ultrasonic immersible transducers, ultrasonic fl at transducer plates, and reactors Valid for: Tabletop housing LG …. T /PRO Industrial housing LG …. F /PRO Industrial housing LG ….
  • Page 2 Copyright & limit of liability This document may not be reproduced, either in full or in extracts, without prior approval of BANDELIN electronic GmbH & Co. KG, hereinafter referred to as BANDELIN. The German original is the binding version of this document. Any differences in the translation are not binding and have no legal effect.
  • Page 3 Operating sequence Identifi es instructions that must be followed in the described  instructions sequence. 23366b GB/2019-07 3 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 4: Table Of Contents

    General use ........................18 Maintenance and cleaning ..................19 Cleaning and care ......................19 Warehousing / storage ....................19 Maintenance and repair .....................19 Maintenance .........................19 4 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 5 Taking the unit out of service ..................28 Key words - not applicable - ....................28 Informative appendices Housing versions 23366b GB/2019-07 5 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 6: Product Description

    • A 19" plug-in module can also be optionally selected (10) in place of the industrial housing. 6 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 7 SONOREX TECHNIK LG 2002 T SONOREX TECHNIK LG 6040 F PRO SONOREX TECHNIK LG 6040 F PRO as a 19" plug-in module 23366b GB/2019-07 7 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 8: Mode Of Operation

    A declaration of conformity can be requested from the manufacturer by providing the serial number. 8 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 9: Technical Data

    Permissible relative humidity up to 31 °C: 80 % Permissible relative humidity up to 40 °C: 50 % Condensation not allowed. Only for indoor operation. 23366b GB/2019-07 9 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 10 It is suitable for use in facilities and areas which are directly connected to a public low- voltage supply network, e.g. medical laboratory facilities. 10 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 11: Warning And Safety Precautions

    • In the case of defects, only authorised skilled personnel or the manufacturer may repair the generator. 23366b GB/2019-07 11 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 12: Preparation

    600 mm deep, in order to offer suffi cient space for the HF plug and mains connection. In addition, adequate ventilation from the front and rear must be ensured. 12 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 13: Hf Connection For Ultrasonic Transducer

    The minimum connected output of 300 W per module must be upheld. 23366b GB/2019-07 13 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 14: Remote Control Connection

     Verify that the power switch is in the "off" position.  Connect the cables (HF cable and mains cable). 14 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 15: Operation

    The power is continuously adjustable from 10 to 100 %. By turning it, the power for all modules is set at the same time. HF switch: Switching the power output on and off. 23366b GB/2019-07 15 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 16: Power Modules

    The LED for the switch is lit green when the switch is pressed and indicates that the module is ready for operation. 16 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 17: Use

    - If one of the red LEDs lights up or starts fl ickering after start-up, an operating fault has occurred, see chapter 6.2. 23366b GB/2019-07 17 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 18: General Use

     To turn the generator off, press the mains switch - set it to "0". For additional care instructions, see chapter 5. 18 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 19: Maintenance And Cleaning

    During extended periods without use, the generator should be stored in a cool, dry place. Maintenance and repair Maintenance The ultrasonic generator requires no maintenance. 23366b GB/2019-07 19 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 20: Error Analysis

    Turn on ACTIVE on all modules. (LED should light up green.) If the LED is not lit up, the affected module must be removed from the generator. 20 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 21 - Consult manufacturer Problems with Transducer frequency Flickers Flickers Flickers the ultrasonic of generator and Consult manufacturer transducers transducer different? 23366b GB/2019-07 21 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 22: Error-Free State (Control)

    - on the control module all presently illuminated LEDs will fl ash. - on the processor module error message on the display. 22 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 23: Short-Circuit And Open Circuit (Transducer)

    SONOBLOC tube reactor. During unattended operation, adequate safety measures should be enforced in order to avoid damage caused by dry running. 23366b GB/2019-07 23 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 24: Customer Service

    The form can be downloaded from the Internet as a PDF fi le: www.bandelin.com - Downloads ... 24 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 25: Replacement Of A Module Or Removal Of A Dummy Plate

    Any empty slots should always be sealed on the front using dummy plates, due to the cool air conduction in the generator. 23366b GB/2019-07 25 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 26: Accessories

    Minutes once the set time expires. The time can be shortened by turning the knob in the opposite direction. 26 / 30 23366b GB/2019-07 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 27: Processor Module Pro 3

    - Choice of operating readiness (activation/ - Setting of the output power in % deactivation) - DEGAS (degassing function) - DEGAS (degassing function) 23366b GB/2019-07 27 / 30 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 28: Preparations

    BANDELIN recommends the TICKOPUR or STAMMOPUR concentrates by DR. H. STAMM GmbH, which have been especially developed for ultrasound use and which optimally utilise the ultrasound.
  • Page 29 Housing versions Tabletop housing Example: LG 3020 T Generator types: LG …. T with CONTROL CONTROL TEMPERATURE TEMPERATURE control module SM 3 or TRANSDUCER TRANSDUCER LG …. T PRO ACTIVE ACTIVE with processor module PRO 3 POWER START STOP Equipment: 1 power switch = button on the rear side 1 control module SM 3 or Control...
  • Page 30 Note: The user instructions in this and other languages, as well as further information, can be found in the enclosed CD.