Summary of Contents for BANDELIN SONOPULS

  • Page 1 User instructions Ultrasonic homogenisers Ultrasonic homogeniser HD 2070.2 valid for: HD 2070.2 Volumes: 1 ml - 200 ml HD 2200.2 Volumes: 2 ml - 1000 ml 51506-002 GB/2020-10...
  • Page 2 Copyright and disclaimer This document may not be reproduced, whether in full or in part, without the prior approval of BANDELIN electronic GmbH & Co. KG, hereinafter “BANDELIN”. The German-language original is the binding version of this document. Any diff erences in the translation are not binding and have no legal eff...
  • Page 3 Identifi es instructions that must be followed  Instructions in the described sequence. 51506-002 GB/2020-10 3 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 4: Table Of Contents

    Mounting and dismounting of micro and tapered tips and long probes ......26 Dismounting and mounting of the standard and booster horns ........27 4 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 5 Optional accessories ....................36 Consumable materials ....................37 Decommissioning ......................37 Keyword index ......................38 General information Tools for mounting/dismounting 51506-002 GB/2020-10 5 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 6: Product Description

    • Panel-mounted plug (8) with fuse holder • Ultrasonic socket (9) and/or ultrasonic transducer • Remote control connector (10) 6 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 7: Basic Working Principle

    A declaration of conformity can be requested from the manufacturer by providing the serial number. 51506-002 GB/2020-10 7 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 8: Technical Data

    In the case of highly-viscous media, this can also result in the desired amplitude not always being reached. 8 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 9 Technical measurement checks, MTK (section 11): not applicable e-procurement e-cl@ss: HD device classifi cation: 32-08-02-02 HD accessories classifi cation: 32-08-02-05 51506-002 GB/2020-10 9 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 10: Technical Data, Ultrasonic Transducers

    L  Ultrasonic operation OFF 5V H H Ultrasonic operation ON Output As with contact 4, but with signal inverted 10 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 11: Electromagnetic Compatibility (Emc)

    It is suitable for use in institutions and other areas that are directly connected to a public low-voltage power supply, e.g., medical laboratory facilities. 51506-002 GB/2020-10 11 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 12: Warnings And Safety Precautions

    • Before any mounting or dismounting (Chapter 4.4) of probes or standard/booster horns as well as accessories, turn off the device and disconnect the ultrasonic transducer from the ultrasonic generator. 12 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 13 • Repairs are only to be conducted by authorised skilled personnel or by the manufacturer. • Defective parts must only be replaced with original parts or parts of the same quality! 51506-002 GB/2020-10 13 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 14: Preparation

    • Avoid any contact between the contact pins on the ultrasonic transducer's plug, since the piezo elements could generate electric loads through temperature fl uctuations  with a possibility of slight electric shocks. 14 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 15: Start-Up

    Control LED green light: Ultrasonic output red light: Error messages fl ashing red: Warning messages Off : Standby mode (PAUSE) 51506-002 GB/2020-10 15 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 16: Turning The Homogeniser On/Off

    (inverse view) of the selected parameter, the desired value is set by turning the rotary knob. By pressing the “START/STOP” button, the editing mode is exited. 16 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 17: Sonication Time [Time]

    1 to 99 minutes 1 to 59 seconds proceed to next set value or operating parameter START back to stand-by mode STOP 51506-002 GB/2020-10 17 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 18: Pulsation [Pulse]

    STOP The pulse period duration is the sum of the turn-on and turn-off time t = t 18 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 19: Special Functions

    1 and 255, and can be set by turning the rotary knob. Smaller values result in a darker image and larger values result in a lighter image. The default value is 240. 51506-002 GB/2020-10 19 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 20: Activating / Deactivating The Ultrasound

    Once the maximum displayable time has been reached and exceeded, the time display will start again at 00:00. 20 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 21: Usage

     Position the sonication vessel below the ultrasonic transducer in such a manner that the probe  Set the immersion depth for the probe (approx. 1 - 2 cm). 51506-002 GB/2020-10 21 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 22  Clean the probe and check the wear on the sound emitting surface at regular intervals, see Chapter 5.1. 22 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 23: Selecting A Suitable Probe

    100 % amplitude setting Amplitude values may diff er slightly from the indicated value due to material and manufacturing tolerances. 51506-002 GB/2020-10 23 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 24: Mounting And Dismounting Of The Probes

    The mounting surfaces are the contact surfaces between the individual accessory parts, e.g. between the standard or booster horn and the probe. 24 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 25: Mounting And Dismounting The Titanium Plates

    TT 13, TT 13 FZ, TT 25 TT 13, TT 13 FZ, TT 25 unscrew Sickle spanner HS 40/42 lying atop work surface 51506-002 GB/2020-10 25 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 26: Mounting And Dismounting Of Micro And Tapered Tips And Long Probes

     Dismount is conducted in the reverse direction. Disassembly Mounting Sickle spanner HS 40/42 Spanner here: Spanner SW 10 26 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 27: Dismounting And Mounting Of The Standard And Booster Horns

    fi rmly in the opposite direction. Ultrasonic transducer Standard and/or booster horn Vigorously turn sickle spanner HS 40/42 long, in the opposite direction 51506-002 GB/2020-10 27 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 28 The ultrasonic oscillating system and its electrical connections would be damaged as a result. 28 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 29: Cleaning And Maintenance Of The Homogeniser

    • Housing is to be wiped off only from the outside, use a suitable surface disinfectant if needed. Afterwards, allow to dry off or wipe dry. 51506-002 GB/2020-10 29 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 30: Treatment Of Contaminated Parts In The Ultrasonic Transducer, Vessels And Accessories Pertaining To The Medical Fi Eld

    During extended periods without use, the homogeniser should be stored in a cool, dry place. The ultrasonic transducer should be covered in order to protect the electronics from outside contamination. 30 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 31: Maintenance And Repair

    >2s start scan frequency scan frequency START contrast contrast STOP V xxxx 199547 Hz V xxxx 199547 Hz 51506-002 GB/2020-10 31 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 32 The ultrasonic oscillating system and its electrical connections would be damaged as a result. 32 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 33: Troubleshooting

    • If it was possible to remedy the error, the display indicator should be deleted by turning off and on again. 51506-002 GB/2020-10 33 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 34 If it is not possible to rectify the error using these short instructions, please contact your local specialist dealer or write us to the address below. 34 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 35: Repairs And Service

    The form can be downloaded from our website as a PDF fi le: www.bandelin.com – Download ... 51506-002 GB/2020-10 35 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 36: Accessories

    The sonication of liquids generates noise. The sound proof box mutes the sound emission up to approximately 30 dB(AU) LS 40 36 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 37: Consumable Materials

    • Metal accessories such as probes or standard horns should be decontaminated and disposed of as metal waste. • The packing is recyclable. 51506-002 GB/2020-10 37 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 38: Keyword Index

    7, 12, 21, 26, 30 Mounting 8, 12, 13, 14, 24, 25, 26, 27, 28 Mounting surface 24, 25, 26, 28, 34 38 / 42 51506-002 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 39 Threaded bolts 28, 34 Titanium plate 7, 12, 25, 29, 30, Tool 13, 24, 34 Type plate 6, 9, 14 51506-002 GB/2020-10 39 / 42 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 40 21, 22, 24, 27, 28, 30, 31, 32, 33, 34, 3, 13, 33 Viscosity 8, 20, 21 Voltage source 11, 12 BANDELIN electronic GmbH & Co. KG www.bandelin.com Zertifi ziert nach Heinrichstraße 3 – 4 info@bandelin.com ISO 9001 12207 Berlin ...
  • Page 41 Tools for mounting/dismounting Probes, standard horns and booster horns are highly-sensitive parts that must be mounted and dismounted with the greatest care. For this reason, only use the following keys for mounting/dismounting of probes from standard or booster horns, as well as of standard or booster horns from the ultrasonic transducer: Spanner Usage Type...
  • Page 42 Please note: The user instructions in this and other languages, as well as further information, can be found on the enclosed CD.

Table of Contents