BANDELIN Sonoplus HD4050 User Instructions

BANDELIN Sonoplus HD4050 User Instructions

Ultrasonic homogenisers
Table of Contents

Advertisement

Quick Links

User Instructions
7
Ultrasonic homogenisers
Valid for:
HD 4050
Volume:
HD 4100
Volume:
HD 4200
Volume:
HD 4400
Volume:
51376-010 GB/2020-10
Ultrasonic homogeniser HD 4100
0.5 ml - 100 ml
2 ml - 200 ml
5 ml - 1000 ml
100 ml - 3000 ml

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sonoplus HD4050 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BANDELIN Sonoplus HD4050

  • Page 1 User Instructions Ultrasonic homogenisers Ultrasonic homogeniser HD 4100 Valid for: HD 4050 Volume: 0.5 ml - 100 ml HD 4100 Volume: 2 ml - 200 ml HD 4200 Volume: 5 ml - 1000 ml HD 4400 Volume: 100 ml - 3000 ml 51376-010 GB/2020-10...
  • Page 2 Copyright & limit of liability This document may not be reproduced, either in full or in extracts, without prior approval of BANDELIN electronic GmbH & Co. KG, hereinafter referred to as BANDELIN. The German original is the binding version of this document. Any diff erences in the translation are not binding and have no legal eff...
  • Page 3 Identifi es instructions that must be followed in the described  Handling instructions sequence. 51376-010 GB/2020-10 3 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 4: Table Of Contents

    General use ........................24 Selecting a suitable probe .................... 26 4.3.1 Mounting and dismounting of the probes ..............27 4 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 5 Consumable materials ....................40 Taking the unit out of service ..................40 Key words ........................41 Informative appendices Tools for mounting/dismounting 51376-010 GB/2020-10 5 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 6: Product Description

    Rear side of the ultrasonic generator: • Mains socket (10) with fuse holder • Remote control connector(11) • RS 232 interface (12) 6 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 7: Mode Of Operation

    A declaration of conformity can be requested from the manufacturer by providing the serial number. 51376-010 GB/2020-10 7 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 8: Technical Data

    In the case of highly viscous media, this can also result in the desired amplitude not always being reached. depending on the connected ultrasonic converter 8 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 9: Technical Data, Ultrasonic Converters

    EMC directions; information in this regard is found in chapter 1.4.4 e-procurement e-cl@ss: HD device classifi cation: 32-08-02-02 HD accessories classifi cation: 32-08-92-05 51376-010 GB/2020-10 9 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 10: Electromagnetic Ambient Conditions (Emc)

    With all other modes of operation, the input works as an edge-controlled changeover switch. The input resistance measures approx. 50 kΩ. 10 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 11 The inputs and outputs of the remote control connector and RS-232 interface may only be connected with devices of protection class I that are connected to the same mains supply circuit. 51376-010 GB/2020-10 11 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 12: Warnings And Safety Precautions

    • Only use the prescribed tool for mounting and dismounting (see appendix A). • Do not use any bent probes ( unstable operation, loss of power). 12 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 13: Preparation

    Before startup, the ultrasonic homogeniser is to be left to stand at its operating location for 2 hours so that it may adapt to the ambient conditions. 51376-010 GB/2020-10 13 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 14: Scope Of Delivery

    Connect to a grounded socket only if type is suitable. 14 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 15: Start-Up

    Ultrasound output blinking green: Remote control through the RS 232 interface red light: Error messages blinking red: Warning messages 51376-010 GB/2020-10 15 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 16: Turning The Homogeniser On/Off

    . If the parameter has number values that can be edited, the editing mode is then activated with the arrow key . In the marked area (inverse view) of the parameter, the desired value can be 16 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 17: Sonication Time [Time Set]

    0.000 kJ Energy 0.000 kJ START STOP back to stand-by mode proceed to next set value or operating parameter 51376-010 GB/2020-10 17 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 18: Pulsation [Pulsation]

    The pulse period duration is the sum of the turn-on and turn-off time t = t 18 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 19: Temperature Monitoring [Temperature]

    Pulsation 4.0s 4.0s Temperature 31°C No sensor: ---°C Energy 0.000 kJ START STOP back to stand-by mode 51376-010 GB/2020-10 19 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 20: Miscellaneous Functions And Settings

    The default value is 22. probe check scan frequency contrast operating mode Ampl. display Energy batch mode 03.01 - 2016-08-085 20 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 21: Loading / Saving Sonication Programs

    Pulsation Temp alarm at 0° Temp control load []* store []* load []* store []* quit [start] quit [start] 51376-010 GB/2020-10 21 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 22: Batch Operation (Batch Processing)

    Note: In this operating mode no more changes of settings are possible within the stand-by mode or ultrasonic operation. 22 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 23: Activating / Deactivating The Ultrasound

    • The displayed value for energy is just a reference value and does nocht correspond to the acoustic energy actually introduced. 51376-010 GB/2020-10 23 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 24: Use

     Set the immersion depth for the probe (approx. 10 -20 mm).  If needed, connect the temperature sensor and position it in the medium. 24 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 25  Clean the probe and check the wear on the sound emitting surface at regular intervals, see chapter 5.1. 51376-010 GB/2020-10 25 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 26: Selecting A Suitable Probe

    After technical updating of the probes, the data may be changed. The stored data in the program are always valid! 26 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 27: Mounting And Dismounting Of The Probes

    The tool required for mounting/ dismounting is included in the scope of supply. The mounting surfaces are the contact surfaces between the standard/booster horn and the probe. 51376-010 GB/2020-10 27 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 28: Mounting And Dismounting The Titanium Fl At Tips

    Sickle spanner HS 40/42 laying atop work surface. screw on TT 213 TT 213 unscrew Sickle spanner laying atop work surface. 28 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 29: Mounting And Dismounting Of Titanium Probes

     With the UW 50 use sickle spanner HS 25/28 - the probe is mounted directly onto the UW 50.  Dismount in the reverse order. Dismounting Assembly Sickle spanner HS 40/42 Spanner here: Spanner SW 10 51376-010 GB/2020-10 29 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 30: Dismounting And Mounting The Standard/Booster Horns

     One sickle spanner is part of the s cope of delivery of one standard/booster horn. Ultrasonic converter Standard/booster horn Vigorously turn sickle spanner HS 40/42 long, in the opposite direction 30 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 31 The ultrasonic oscillating system and its electrical connections would be damaged as a result. 51376-010 GB/2020-10 31 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 32: Cleaning And Maintenance Of The Homogeniser

    • Housing is to be wiped off only from the outside, use a suitable surface disinfectant if needed. Afterwards, allow to dry off or wipe dry. 32 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 33: Treatment Of Contaminated Parts In The Ultrasonic Converter, Vessels And Accessories Pertaining To The Medical Fi Eld

    During extended periods without use, the homogeniser should be stored in a cool, dry place. The ultrasonic converter should be covered in order to protect the electronics from outside contamination. 51376-010 GB/2020-10 33 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 34: Maintenance And Repair

    01.02 - 2014-08-20 01.02 - 2014-08-20 probe check scan frequency contrast START operating mode Ampl. STOP batch mode 01.02 - 2014-08-20 34 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 35: Error Analysis

    10 minutes, if necessary check with a homogenizer switches off temperature sensor that the operating temperature of the GM has dropped to < 50 °C. 51376-010 GB/2020-10 35 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 36 4.3.1. Wrong resonance frequency? Conduct frequency scan, see chapter 6.2 (search frequency). 36 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 37: Repairs And Service

    Fax: +49-(0)-30 – 76 88 02 00 13 In the case of returns, the general terms of delivery of BANDELIN electronic GmbH & Co. KG shall apply. In addition, the homogeniser must be cleaned and decontaminated (if necessary), see the following chapter.
  • Page 38: Decontamination Certifi Cate

    03.01 - 2016-08-085 The software version provided here is only an example, the actual specifi cations may diff er. 38 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 39: Accessories

    The sonication of liquids generates noise. The sound proof box mutes the sound emission up to approximately 30 dB(AU) LS 40 51376-010 GB/2020-10 39 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 40: Consumable Materials

    • Metal accessories such as probes or standard horns should be decontaminated and disposed of as metal waste. • The packing is recyclable. 40 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 41: Key Words

    Laboratory fi eld Liquid 7, 12, 13, 24, 39 Energy 7, 8, 16, 17, 23 Error message 15, 20, 34, 35 51376-010 GB/2020-10 41 / 46 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 42 Protection class Suitable for continuous operation Pulsation time 8, 16 Surface (sound-emitting) 25, 32, 33, 34 Purpose 7, 9 42 / 46 51376-010 GB/2020-10 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 43 8, 10, 17, 18, 19, Ultrasound output 15, 25 3, 13, 35 Viscosity 8, 23, 24 Voltage source 10, 12 BANDELIN electronic GmbH & Co. KG www.bandelin.com Zertifi ziert nach Heinrichstraße 3 – 4 info@bandelin.com ISO 9001 12207 Berlin  +49 30 768 80-0...
  • Page 45 Tools for mounting/dismounting Probes and standard/booster horns are highly-sensitive parts that must be mounted and dismounted with the greatest amount of care. For this reason, only use the following spanners for the mounting/dismounting of probes from standard/booster horns, as well as of standard/booster horns from the ultrasonic converter: Spanner Type Spanner MS 10, long...
  • Page 46 Important: The Instructions for Use in this and other languages, as well as further information, can be found on the enclosed CD.