Capitani SKYCAP1 Instruction Manual page 34

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
Problem
Selecting the
distribution button(A-
B) you cannot get a
beverage
The capsule is not
ejected
The lever (1) will not
slide properly
Problem
When button (B) or (C) is
pressed, milk is not dispensed
Steam is coming out of the
beaker (13)
Solution
1) Fill the tank with water
2) Check if the water tank is well located
3) Lift the lever to permit air outlet take the capsule
off and wait for a while to let the pump be
cool, close the lever again and select the
distribution button(A-B)
4) Empty the capsule drawer and reset the coffee function by switching
the machine off and on again.
If the problem persists, contact the local service centre.
Close the lever (1), then slowly open it again
Press the start button (A-B) and slowly open the lever as water is being
delivered (1)
Press the start button (A-B), then open and close the lever (1) several
times while water is being dispensed
Causes
the milk beaker (13) is empty fill the beaker (13) with milk
the lid is not fitted on the beaker
(13)
the beaker (13) is not correctly inserted in its seat insert the
the connectors of the beaker (13)
are not correctly inserted
button (B) is programmed to
dispense coffee
the beaker (13) is not correctly
inserted in its seat
worn gaskets
32
Corrective action
without exceeding the level
indicated
close the milk beaker (13)
with the lid.
beaker (13) correctly in its
seat, pressing it against the
machine right to the bottom
Clean all the connectors and
the pipe and insert them
correctly in the seats of the
beaker (13)
programme button (B) to
dispense milk as indicated on
page 28
insert the beaker (13) correctly
in its seat, pressing it against
the machine right to the bottom
replace the gaskets, applying
to the service centre

Advertisement

Table of Contents
loading

This manual is also suitable for:

609ec

Table of Contents