BFT ZARA BTL2 Installation Manual page 11

Hide thumbs Also See for ZARA BTL2:
Table of Contents

Advertisement

Available languages

Available languages

Terminal
70
71
72
73
74
75
Y
#
(*) Other voltages available on request
(*) If "D" type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.
WARNING! The autoset operation must be performed only once you have che-
cked that the leaf is moving accurately (opening/closing) and that the mechanical
stops and end stops are positioned correctly.
You must run an autoset cycle whenever the position of the end stops, the motor
force (T2) or the slow-down distance (T3) are changed. .
WARNING! While the autoset function is running, the obstacle detection function
is not active. Consequently, the installer must monitor the automated device's
movements and keep people and property out of range of the automated device.
WARNING: the torque values set by the autoset function refer to the motor force
set during the autoset cycle. if motor force is edited, an autoset opening and
closing cycle will need to be performed again.
WARNING: check that the force of impact measured at the points provided for
by standard EN 12445 is lower than the value laid down by standard EN 12453.
Setting sensitivity incorrectly can result in damage to property and injury to
people and animals.
SOLENOID LOCK
WARNING: In the case of leaves longer than 3m, it is essential to install
a solenoid lock.
KEYS
KEYS
Description
Add Start Key
S1
associates the desired key with the Start command.
Add Pedestrian Key
S2
associates the desired key with the pedestrian command.
S2
Confirms the changes made to parameter settings and operating
>5s
Erase List
S1+S2
WARNING! Erases all memorized transmitters from the
>10s
receiver's memory.
Pressed BRiEFLY, it gives the START command.
S3
HELD DOWN (>5 sec.), it activates the AUTOSET function.
LED INDICATORS:
POWER
Steadily lit: - Mains power on - Board powered - Fuse F1 intact
START
Lit: START input activated
OPEN
Lit: OPEN input activated
STOP
Unlit: STOP input activated
PHOT
Unlit: PHOT photocell input activated
FAULT 1 PHOT input safety device test input diagnostics
22
- ZARA BTL2
INSTALLATION MANUAL
Definition
Common
STOP, PHOT and BAR inputs common
The command stops movement. (N.C.)
STOP
if not used, leave jumper inserted.
PHOTOCELL input (N.C.).
PHOT (**)
Operation according to "PHOTOCELL/PHOTOCELL DURiNG CLOSiNG" logic. if not used, leave jumper inserted.
FAULT 1
Test input for safety devices connected to PHOT.
BAR safety edge input (N.C.).
Configurable according to the "BAR/ 8K2" logic.
BAR (*)
The command reverses movement for 2 sec.
if not used, leave jumper inserted.
Safety edge input (N.C.).
if not used, leave jumper inserted
BAR/8K2
dip
OFF
BAR /
OFF
BAR CL /
BAR TEST /
OFF
BAR CL TEST /
BAR 8K2 /
OFF
BAR CL 8K2
(*)
ON
ON
ON
ON
FAULT 2
Test input for safety devices connected to BAR.
Antenna input.
ANTENNA
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies
close to the antenna can interfere with radio reception. if the transmitter's range is limited, move the antenna
SHiELD
to a more suitable position.
Description
Only active on FW < 2.05
Only active on FW ≥ 2.05
Safety
Safety edge
edge
operation
check dip
dip
OFF
OFF
NC input, no verification, reversal while opening and closing (BAR)
OFF
ON
NC input, no verification, reversal only when closing, stop when
opening (BAR CL)
ON
OFF
NC input, with verification, reversal while opening and closing
(BAR TEST)
ON
ON
NC input, with verification, reversal only when closing, stop when
opening (BAR CL TEST)
OFF
OFF
8K2 input, reversal when opening and closing (BAR 8K2)
OFF
ON
8K2 input, reversal only when closing, stop when opening (BAR
CL 8K2)
ON
OFF
---
ON
ON
---
BAR
Unlit: BAR safety edge input activated
FAULT 2 BAR input safety device test input diagnostics
Lit: the limitswitch closing of motor 1 is free
SWC1
Unlit: motor 1 closing limit switch input activated
Lit: the limitswitch opening of motor 1 is free
SWO1
Unlit: motor 1 opening limit switch input activated
Lit: the limitswitch closing of motor 2 is free
SWC2
Unlit: motor 2 closing limit switch input activated
Lit: the limitswitch opening of motor 2 is free
SWO2
Unlit: motor 2 opening limit switch input activated
Unlit: no error
ERR
LiT: see error diagnostics table
Unlit: remote programming not active
Radio LED only flashing: Remote programming active, waiting for
hidden key.
RADIO
(GREEN)
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated
Lit: Set key pressed / Autoset completed successfully
Flashes three times: Autoset in progress
Fast flashing 10s: Autoset failed
SET
Flashing in sync with Radio LED: Transmitter deletion in progress
Lit 1s: Start/Stop after key S3 pressed
Lit 10s: Autoset completed correctly
9) ADJUSTMENT PROCEDURE
- Before turning the unit on, check electrical connections.
- Set the following parameters: Automatic Closing Time, motor force, slow-down
distance.
- Set the logics.
- Run the autoset function.
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
not overheated by a considerable number of consecutive operations)
10) INSTALLATION TEST PROCEDURE

Advertisement

Table of Contents
loading

Table of Contents