G6A
■Approved Standards
To order the model that is certified for
the UL/C-UL standards, add "-US" to
the end of the model number.
■Precautions
●Please refer to "PCB Relays Common Precautions" for correct use.
Correct Use
●Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON
continuously for long periods (without switching) can lead to
unstable contacts because the heat generated by the coil itself
will affect the insulation, causing a film to develop on the contact
surfaces. We recommend using a latching relay
(magnetic-holding relay) in this kind of circuit. If a single-side
stable model must be used in this kind of circuit, we recommend
using a fail-safe circuit design that provides protection against
contact failure or coil burnout.
●Relay Handling
When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep
the solvent temperature to less than 40°C. Do not put the Relay
in a cold cleaning bath immediately after soldering.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
UL/C-UL Recognized.
Contact
Classification
Coil ratings
form
Single-side
stable
DPDT
Latching
3 to 48 VDC
(2c)
Low-sensitivity
High-sensitivity
●Double-switching load in two poles
Double-switching in two poles as shown in the figure below, one
pole and two pole interval may become MBB (Make Before
Break) mechanically according to the timing of the point of
contact switching (By the short-circuit mode), and the
malfunction might be caused.
In such a circuit, direct electric switching should be avoided, and
concern for contact to be carried after the contact of Relay
absolutely switches in condition of no load.
Contact: www.omron.com/ecb
(File No.E41515)
Model
G6A-274P-ST-US
0.6 A, 125 VAC at 40°C
G6AK-274P-ST-US
2 A, 30 VAC at 40°C
G6AU-274P-ST-US
0.6 A, 110 VAC at 40°C
G6A(K)-274P-ST40-US
G6A-274P-ST15-US
+
Load
Contacts
Note: Do not use this document to operate the Unit.
Low Signal Relay
Number of
Contact ratings
test
operations
6,000
G
A
Cat. No. K020-E1-15