LDG Z-100Plus Operation Manual

LDG Z-100Plus Operation Manual

100-watt automatic tuner
Hide thumbs Also See for Z-100Plus:

Advertisement

Z- 100PLUS OP P ERATION
NS MANUAL
L
M
MANUAL RE
EV A
LD
DG Z
Z-100
0Plus
s
100
0-Wa
att
Au
utoma
atic T
Tune
er
LDG E
Electron
nics
1445
Parran Road
d
St
t. Leonard M
MD 20685-29
903 USA
Phone:
410-586-21
77
Fax: 4
410-586-847
75
ldg@ldg
gelectronics.c
com
www.ldg
gelectronics.c
com
PA
GE 1

Advertisement

Table of Contents
loading

Summary of Contents for LDG Z-100Plus

  • Page 1 Z- 100PLUS OP P ERATION NS MANUAL MANUAL RE EV A DG Z Z-100 0Plus 0-Wa utoma atic T Tune LDG E Electron nics 1445 Parran Road t. Leonard M MD 20685-29 903 USA Phone: 410-586-21 Fax: 4 410-586-847 ldg@ldg gelectronics.c...
  • Page 2: Table Of Contents

    Table of Contents Introduction Jumpstart, or “Real hams don’t read manuals!” Specifications An Important Word About Power Levels Important Safety Warning Getting to know your Z-100Plus Front Panel Rear Panel Installation Operation Basic Tuning Operation Toggle Bypass Mode: Initiate a Memory Tune Cycle:...
  • Page 3: Introduction

    Power up the transceiver and select the desired operating frequency. Select AM, FM, CW, or PKT mode, and then key down to transmit a carrier Push and hold the TUNE button on the front of the Z-100Plus for one second (until the Tuning LED comes on), then release.
  • Page 4: Specifications

    Includes 1 foot Icom and Yaesu 857/897 interface cable and 1 foot coaxial cable jumper. AN IMPORTANT WORD ABOUT POWER LEVELS The Z-100Plus is rated at 125 watts maximum power input at most. Many ham transmitters and transceivers, and virtually all amplifiers, output well over 125 watts. Power levels that significantly exceed specifications will definitely damage or destroy your Z-100Plus.
  • Page 5: Getting To Know Your Z-100Plus

    The tuner can be placed in bypass mode by pressing the Tune button momentarily. Although a DC coax jack is supplied on the rear of the Z-100Plus, the Z-100Plus may also be powered directly from internal AA or 9V batteries (not supplied); no separate power supply is needed.
  • Page 6: Rear Panel

    Rear Panel The rear panel of the Z-100Plus features five connectors. Antenna connector: Connect the 50-ohm coax antenna feedline to this standard SO-239 connector. GND connector (wing nut): Connect to antenna system ground. Transmitter connector: Connect the 50-ohm coax jumper cable from this standard SO-239 connector to the ANT jack on the back of the transceiver.
  • Page 7: Installation

    INSTALLATION The Z-100Plus tuner is designed for indoor operation only; it is not water resistant. If you use it outdoors (Field Day, for example), you must protect it from the rain. The Z-100Plus is designed for use with coax-fed antennas. If use with longwires or ladder-line-fed antennas is desired, an external balun is required.
  • Page 8: Operation

    OPERA TION Basic Tu ning Operat tion The Z Z-100Plus is s operated f from the fron nt panel TU UNE button on the Z-10 00Plus itself . Two types of t tuning cycle es are availab ble; a memor...
  • Page 9: Initiate A Memory Tune Cycle

    T Tune button n on the front pa anel of the Z Z-100Plus un ntil the Tun ing LED lig ghts up, and keep holdin ng until the T Tuning LED g goes out aga ain.
  • Page 10: Status Indicators

    Tuning LED blinks s 5 times. APPLIC CATION IN NFORMATI Mobile O Operation The Z Z-100Plus is s perfectly s uited to mob bile operatio on. It can be e installed un nder the das shboard along wi ith the transc...
  • Page 11: Mars/Cap Coverage

    In order to install an internal battery supply, the lid of the Z-100Plus must be removed by first removing the four screws on the side of the case. Connection of the battery pack to the Z-100Plus is made via the two battery solder pads at J8 and J9.
  • Page 12: Icom Interfacing

    When interfacing the Z-100Plus with an FT-857 or FT-897 using the Y-ACC cable, the Tune button on the Z-100Plus is used to initiate a tune. The Z-100Plus will automatically key the radio at the current power level during a tuning cycle and un-key when the tuning cycle is complete.
  • Page 13 SWR R meter until l a minimum m SWR is rea ached. The L LDG Electro onics Z-100P Plus automa ates this GE 13...
  • Page 14: The Ldg Z-100Plus

    This allows the Z-100Plus to handle loads that are either greater than or less than 50 ohms. All relays are sized to carry 125 watts continuously.
  • Page 15: A Word About Tuning Etiquette

    Be sure to use a vacant frequency when tuning. With today’s crowded ham bands, this is often difficult. However, causing interference to other hams should be avoided as much as possible. The Z-100Plus’s very short tuning cycle, as little as a fraction of a second, minimizes the impact of tuning transmissions.
  • Page 16: Out Of Warranty Service

    Ask your shipper for a tracking number or a delivery verification receipt. This way you know the product arrived safely at LDG. Be sure to give us your email address so our shipper can alert you online when your product is en-route back to you. We regret that we are not able to provide periodic updates on the status of repairs.
  • Page 17 PAG G E 17...

Table of Contents