Fig. 14 Signal Connection - Beckhoff EP1908 Operating Instructions Manual

Twinsafe ethercat box with 8 fail-safe inputs
Table of Contents

Advertisement

5.2.5.8
Signal connection
Fig. 14: Signal connection
M12 connection
1
2
3
4
Configurable inputs
The inputs 1 to 8 can be occupied as you want with normally closed contacts or normally open
contacts. The corresponding analysis is carried out in the safety PLC.
EP1908
Contact
Channel
1
1
2
3
2
4
5
-
1
3
2
3
4
4
5
-
1
5
2
3
6
4
5
-
1
7
2
3
8
4
5
-
Version: 3.0.0
Signal
Pulse output 1
Input 1
Pulse output 2
Input 2
not connected
Pulse output 3
Input 3
Pulse output 4
Input 4
not connected
Pulse output 5
Input 5
Pulse output 6
Input 6
not connected
Pulse output 7
Input 7
Pulse output 8
Input 8
not connected
Operation
27

Advertisement

Table of Contents
loading

Table of Contents