USI structure = W#16#0003
Table 5- 9
USI structure = W#16#0003
Data block name
USI
The first surplus module is located in slot: <No.>
Slot
Followed by 3 reserved bytes
Reserved
Reserved
Reserved
USI structure = W#16#0004
Table 5- 10
USI structure = W#16#0004
Data block name
USI
Followed by 4 reserved bytes
Reserved
Reserved
Reserved
Reserved
USI structure = W#16#0005
Table 5- 11
USI structure = W#16#0005
Data block name
USI
Followed by 4 reserved bytes
Reserved
Reserved
Reserved
Reserved
IM 155-5 PN ST interface module (6ES7155-5AA00-0AB0)
Manual, 08/2013, A5E03612323-02
Contents
W#16#0003
B#16#20 to B#16#FF
Contents
W#16#0004
Contents
W#16#0005
Interrupts and diagnostic, error, and system alarms
Note
Manufacturer-specific diagnostic data
if the permitted number of I/O
modules is exceeded
Note
Manufacturer-specific diagnostic data
if no U connector is detected on an IM
port
Note
Manufacturer-specific diagnostic data
if there is more than one bus master
module (IM/CPU)
5.3 Alarms
Bytes
2
1
1
1
1
Bytes
2
1
1
1
1
Bytes
2
1
1
1
1