3.1. Continuous Acquisition

Software AD Trigger
Under the combination of continuous acquisition mode and software command trigger, when the
PC sends a start command to the PET-AR400, the module will start to collect data, and every time
the data accumulates to a certain size, it will be sent back to the PC. The process of collecting data
will continue until the PC sends a stop command or the amount of data reaches the target.
The following parameters need to be specified:
 Channels (1 ~ 4)
 Sampling rate (1 ~ 128 k Hz)
 Target count (0 ~ 15000000, 0 means keep collecting data until stop command send)
 Set trigger mode as software trigger mode.
PET-AR400 User Manual
V1.0.0