Power Distribution Board; Power Plug Wiring - Stern Pinball WRESTLEMANIA WWE PRO Service And Operation Manual

Table of Contents

Advertisement

4.14 POWER DISTRIBUTION BOARD

520-5343-00
PINOUT
ID
Type
Pin Description
CN1 .156 in 7-Pin
1
+48 VDC IN
Housing
2
+48 VDC IN
Plug: 045-5259-07
3
+48 VDC IN
Pin: 055-5331-00
4
Key (n/c)
Key: 060-5013-00
5
Ground
6
Ground
7
Ground
CN2 .093 in 3-Pos Plug
1
Line In (100-240 VAC)
Plug: 045-5003-03
2
Neutral
Pin: 055-5013-09
3
Earth Ground
CN3 0.084 in 4-Pos Plug
1
+48 VDC to CPU Node
Plug: 045-5200-04
2
Door Interlock Switch Status
Pin: 055-5033-08
3
Line Voltage Status
4
Ground
CN4 0.084 in 6-Pos Plug
1
Door Interlock Switch +48V
Plug: 045-5200-06
2
Door Interlock Switch +48V
Pin: 055-5033-08
3
Switched 48V Out (to Node 1) GRY/YEL
4
Door Interlock Return Ground GRY/RED
5
Door Interlock Return Ground GRY/RED
6
Ground (to Node 1)
CN5 0.084 in 12-Pos
1
Switched 48V Node Power
Plug
2
Switched 48V Node Power
Plug: 045-5200-12
3
Switched 48V Node Power
Pin: 055-5033-08
4
Switched 48V Node Power
5
Switched 48V Node Power
6
Switched 48V Node Power
7
Node Ground
8
Node Ground
9
Node Ground
10 Node Ground
11 Node Ground
12 Node Ground
Figure 4.14.1. Power Distribution Board 520-5343-00 pinout
WWE and related marks
™ & © 2014 WWE. All Rights Reserved.
ELECTRONIC PINOUTS AND SCHEMATICS

4.15 POWER PLUG WIRING

CAUTION
TO MAINTAIN SAFETY, GROUND WIRE FROM LINE FILTER IS
TO BE MOUNTED FIRST ON GROUNDING STUD AND SECURED
WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED
TO GROUNDING STUD.
REPLACE ALL FUSES WITH CORRECT CURRENT RATINGS!
NORTH AMERICA
Wire
Color
POWER SUPPLY
GRY
GRY
POWER DIST.
GRY
BILL VALIDATOR
(USER INSTALLED OPTION)
-
INTERNATIONAL
BLK
*MFG NOTES:
BLK
1.
ALL DISCREET WIRE IS 16AWG 600V, UL 1015, CSA TYPE TEW.
BLK
2.
NEMA 5-15 OUTLET HAS 14AWG 600V WIRE, UL 1015, CSA TYPE TEW.
3.
GROUND WIRE FROM LINE FILTER IS TO BE MOUNTED FIRST ON GROUNDING STUD
BLK
AND SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED TO
GROUNDING STUD.
WHT
4.
CABLE ARE TO BE MANUFACTURED IN A UL CERTIFIED FACILITY. VENDOR IS TO
PROVIDE A SIGNED U.L. CERTIFICATE OF COMPLIANCE WITH FIRST ARTICLE.
GRN
GRY
GRY/RED
POWER SUPPLY
VIO
POWER DIST.
BLK
GRY
GRY
LINE CORDS
*MFG NOTES:
Part Number
1.
ALL DISCREET WIRE IS 16AWG 600V, UL 1015, CSA TYPE TEW.
034-6012-00
2.
GROUND WIRE FROM LINE FILTER IS TO BE MOUNTED FIRST ON GROUNDING STUD
AND SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED TO
BLK
034-6012-01
GROUNDING STUD.
3.
CABLE ARE TO BE MANUFACTURED IN A UL CERTIFIED FACILITY. VENDOR IS TO
GRY
034-6012-02
PROVIDE A SIGNED U.L. CERTIFICATE OF COMPLIANCE WITH FIRST ARTICLE.
GRY
034-6012-03
GRY
034-6012-04
GRY
034-6012-05
GRY
034-6012-06
GRY
034-6012-07
BLK
034-6012-08
BLK
034-6012-09
BLK
LINE FUSES
BLK
BLK
Line Voltage (Region)
BLK
120V (North America)
220/240v (Europe, Australia,
UK)
Figure 4.15.1. Standard fuses for line connections, 120V and 240V
WWE PRO MANUAL #780-50G1-00
NORTH AMERICA
NEMA 5-15 PREWIRED OUTLET
L
LINE FILTER
G
N
GROUNDING
STUD
INTERNATIONAL
ON/OFF SW
L
LINE FILTER
G
N
GROUNDING
STUD
ON/OFF SW
Description
Line Cord, 3m, 5-15P USA
Line Cord, 3m, CEE77P EUROPE
Line Cord, 3m, BS1363P United Kingdom
Line Cord, 3m, AS-NZS4417P Australia
Line Cord, 3m, CEI23-16P Italy
Line Cord, 3m, SEV1011P Switzerland
Line Cord, 3m, JIS8303P Japan
Line Cord, 3m, SI32P Israel
Line Cord, 3m, BS546P S Africa, India
Line Cord, 3m, IS6538P S. India
Fuse
Type
Current
8 A
Slow Blow MDL 200-5000-05
5 A
Slow Blow MDL 200-5000-01
02/12/15
FUSE
FUSE
05/02/14
AC WIRI
1.00"
2.00"
1:1
SPIKE
05/02/14
1.00"
2.00"
1:1
Part Number
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

500-55g1-00