Power Distribution Board; Power Plug Wiring - Stern Pinball GAME OF THRONES Service And Operation Manual

Table of Contents

Advertisement

For Sales + Purchasing Info, Click Page To Visit BMI Gaming | www.bmigaming.com | + 561-391-7200 | (800) 746-2255
ELECTRONIC PINOUTS AND SCHEMATICS

4.11 POWER DISTRIBUTION BOARD

520-5343-01
ID
Type
Pin
CN1 .156 in 7-Pin
1
Housing
2
Plug: 045-5259-07
3
Pin: 055-5331-00
4
Key: 060-5013-00
5
6
7
CN2 .093 in 3-Pos Plug
1
Plug: 045-5003-03
2
Pin: 055-5013-09
3
CN3 0.084 in 4-Pos Plug
1
Plug: 045-5200-04
2
Pin: 055-5033-08
3
4
CN4 0.084 in 6-Pos Plug
1
Plug: 045-5200-06
2
Pin: 055-5033-08
3
4
5
6
CN5 0.084 in 12-Pos Plug
1
Plug: 045-5200-12
2
Pin: 055-5033-08
3
4
5
6
7
8
9
10
11
12
30
Description
Wire Color
+48 VDC IN
GRY
+48 VDC IN
GRY
+48 VDC IN
GRY
Key (n/c)
-
Ground
BLK
Ground
BLK
Ground
BLK
Line In (100-240 VAC)
BLK
*MFG NOTES:
Neutral
WHT
1.
ALL DISCREET WIRE IS 16AWG 600V, UL 1015, CSA TYPE TEW.
Earth Ground
GRN
2.
NEMA 5-15 OUTLET HAS 14AWG 600V WIRE, UL 1015, CSA TYPE TEW.
3.
GROUND WIRE FROM LINE FILTER IS TO BE MOUNTED FIRST ON GROUNDING STUD
+48 VDC to CPU Node
GRY
AND SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED TO
GROUNDING STUD.
Door Interlock Switch Status GRY/RED
4.
CABLE ARE TO BE MANUFACTURED IN A UL CERTIFIED FACILITY. VENDOR IS TO
PROVIDE A SIGNED U.L. CERTIFICATE OF COMPLIANCE WITH FIRST ARTICLE.
Line Voltage Status
VIO
Ground
BLK
Door Interlock Switch +48V
-
Door Interlock Switch +48V
-
Switched 48V Out (to Node 1) GRY/YEL
Door Interlock Return Ground -
Door Interlock Return Ground -
Ground (to Node 1)
BLK
*MFG NOTES:
Switched 48V Node Power
GRY
1.
ALL DISCREET WIRE IS 16AWG 600V, UL 1015, CSA TYPE TEW.
Switched 48V Node Power
GRY
2.
GROUND WIRE FROM LINE FILTER IS TO BE MOUNTED FIRST ON GROUNDING STUD
AND SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED TO
Switched 48V Node Power
GRY
GROUNDING STUD.
3.
CABLE ARE TO BE MANUFACTURED IN A UL CERTIFIED FACILITY. VENDOR IS TO
Switched 48V Node Power
GRY
PROVIDE A SIGNED U.L. CERTIFICATE OF COMPLIANCE WITH FIRST ARTICLE.
Switched 48V Node Power
GRY
Switched 48V Node Power
GRY
Node Ground
BLK
Node Ground
BLK
Node Ground
BLK
Node Ground
BLK
Node Ground
BLK
Node Ground
BLK
GAME OF THRONES PRO MANUAL 500-55G4-01

4.12 POWER PLUG WIRING

CAUTION
TO MAINTAIN SAFETY, GROUND WIRE FROM LINE FILTER
IS TO BE MOUNTED FIRST ON GROUNDING STUD AND
SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE
ATTACHED TO GROUNDING STUD.
NORTH AMERICA
REPLACE ALL FUSES WITH CORRECT CURRENT RATINGS!
NORTH AMERICA
LINE FILTER
GROUNDING
STUD
INTERNATIONAL
POWER SUPPLY
POWER DIST.
BILL VALIDATOR
(USER INSTALLED OPTION)
INTERNATIONAL
LINE FILTER
GROUNDING
STUD
POWER SUPPLY
POWER DIST.
LINE CORDS
Part Number
Description
034-6012-00
Line Cord, 3m, 5-15P USA
034-6012-01
Line Cord, 3m, CEE77P EUROPE
034-6012-02
Line Cord, 3m, BS1363P United Kingdom
034-6012-03
Line Cord, 3m, AS-NZS4417P Australia
034-6012-04
Line Cord, 3m, CEI23-16P Italy
034-6012-05
Line Cord, 3m, SEV1011P Switzerland
034-6012-06
Line Cord, 3m, JIS8303P Japan
034-6012-07
Line Cord, 3m, SI32P Israel
034-6012-08
Line Cord, 3m, BS546P S Africa, India
034-6012-09
Line Cord, 3m, IS6538P S. India
LINE FUSES
Line Voltage (Region)
Fuse
Current
120V (North America)
8 A
220/240v (Europe, Australia,
5 A
UK)
NEMA 5-15 PREWIRED OUTLET
FUSE
L
G
N
ON/OFF SW
FUSE
L
G
1.00"
2.00"
N
ON/OFF SW
1.00"
Type
Part Number
Slow Blow MDL
200-5000-05
Slow Blow MDL
200-5000-01
™ & © 2015 Home Box Office, Inc.
05/02/14
AC WIRING DIAGR
1:1
X
SPIKE BB
05/02/14
2.00"
1:1
SPIKE BB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Game of thrones pro500-55g4-01

Table of Contents