Power Distribution Board; Power Plug Wiring - Stern Pinball 500-55L5-01 Manual

Guardians of the galaxy
Table of Contents

Advertisement

ELECTRONIC PINOUTS AND SCHEMATICS

4.16 POWER DISTRIBUTION BOARD

520-5343-01
ID
Type
Pin Description
CN1 .156 in 7-Pin Housing
1
+48 VDC IN
2
+48 VDC IN
Plug: 045-5259-07
3
+48 VDC IN
Pin: 055-5331-00
4
Key (n/c)
5
Ground
Key: 060-5013-00
6
Ground
7
Ground
CN2 .093 in 3-Pos Plug
1
Line In (100-240 VAC)
2
Neutral
Plug: 045-5003-03
3
Earth Ground
Pin: 055-5013-09
CN3 0.084 in 4-Pos Plug
1
+48 VDC to CPU Node
2
Door Interlock Switch Status
Plug: 045-5200-04
3
Line Voltage Status
Pin: 055-5033-08
4
Ground
CN4 0.084 in 6-Pos Plug
1
Door Interlock Switch +48V
2
Door Interlock Switch +48V
Plug: 045-5200-06
3
Switched 48V Out (to Node 1) GRY/YEL
Pin: 055-5033-08
4
Door Interlock Return Ground -
5
Door Interlock Return Ground -
6
Ground (to Node 1)
CN5 0.084 in 12-Pos Plug
1
Switched 48V Node Power
2
Switched 48V Node Power
Plug: 045-5200-12
3
Switched 48V Node Power
Pin: 055-5033-08
4
Switched 48V Node Power
5
Switched 48V Node Power
6
Switched 48V Node Power
7
Node Ground
8
Node Ground
9
Node Ground
10
Node Ground
11
Node Ground
12
Node Ground
CN6 .156 in 3-Pos
1
Ground
Plug: 045-5259-03
2
Ground
Pin:055-5331-00
3
+12VDC
(18awg)
CN7 .084 2-Pos
1
+48 VDC to CPU Node
Plug: 045-5200-02
2
Ground
Pin:055-5033-08
34
Wire Color
GRY
GRY
GRY
-
BLK
BLK
BLK
BLK
WHT
*MFG NOTES:
GRN
1.
ALL DISCREET WIRE IS 16AWG 600V, UL 1015, CSA TYPE TEW.
2.
NEMA 5-15 OUTLET HAS 14AWG 600V WIRE, UL 1015, CSA TYPE TEW.
3.
GROUND WIRE FROM LINE FILTER IS TO BE MOUNTED FIRST ON GROUNDING STUD
GRY
AND SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED TO
GROUNDING STUD.
GRY/RED
4.
CABLE ARE TO BE MANUFACTURED IN A UL CERTIFIED FACILITY. VENDOR IS TO
PROVIDE A SIGNED U.L. CERTIFICATE OF COMPLIANCE WITH FIRST ARTICLE.
VIO
BLK
-
-
BLK
*MFG NOTES:
GRY
1.
GRY
ALL DISCREET WIRE IS 16AWG 600V, UL 1015, CSA TYPE TEW.
2.
GROUND WIRE FROM LINE FILTER IS TO BE MOUNTED FIRST ON GROUNDING STUD
AND SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED TO
GRY
GROUNDING STUD.
3.
CABLE ARE TO BE MANUFACTURED IN A UL CERTIFIED FACILITY. VENDOR IS TO
GRY
PROVIDE A SIGNED U.L. CERTIFICATE OF COMPLIANCE WITH FIRST ARTICLE.
GRY
GRY
BLK
BLK
BLK
BLK
BLK
BLK
-
-
-
-
-
GUARDIANS OF THE GALAXY PRO MANUAL 500-55L5-01

4.17 POWER PLUG WIRING

CAUTION
TO MAINTAIN SAFETY, GROUND WIRE FROM LINE FILTER
IS TO BE MOUNTED FIRST ON GROUNDING STUD AND
SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE
ATTACHED TO GROUNDING STUD.
NORTH AMERICA
REPLACE ALL FUSES WITH CORRECT CURRENT RATINGS!
NORTH AMERICA
LINE FILTER
GROUNDING
STUD
INTERNATIONAL
POWER SUPPLY
POWER DIST.
BILL VALIDATOR
(USER INSTALLED OPTION)
INTERNATIONAL
LINE FILTER
GROUNDING
STUD
POWER SUPPLY
POWER DIST.
LINE CORDS
Part Number
Description
034-6012-00
Line Cord, 3m, 5-15P USA
034-6012-01
Line Cord, 3m, CEE77P EUROPE
034-6012-02
Line Cord, 3m, BS1363P United Kingdom
034-6012-03
Line Cord, 3m, AS-NZS4417P Australia
034-6012-04
Line Cord, 3m, CEI23-16P Italy
034-6012-05
Line Cord, 3m, SEV1011P Switzerland
034-6012-06
Line Cord, 3m, JIS8303P Japan
034-6012-07
Line Cord, 3m, SI32P Israel
034-6012-08
Line Cord, 3m, BS546P S Africa, India
034-6012-09
Line Cord, 3m, IS6538P S. India
LINE FUSES
Line Voltage (Region)
Fuse
Current
120V (North America)
8 A
220/240v (Europe, Australia,
5 A
UK)
NEMA 5-15 PREWIRED OUTLET
FUSE
L
G
N
ON/OFF SW
FUSE
L
G
1.00"
2.00"
N
ON/OFF SW
1.00"
2.00"
Type
Part Number
Slow Blow MDL
200-5000-05
Slow Blow MDL
200-5000-01
MARVEL.COM
© MARVEL
05/02/14
AC WIRING DIAGR
1:1
X
SPIKE BB
05/02/14
1:1
SPIKE BB

Advertisement

Table of Contents