Power Distribution Board; Power Plug Wiring - Stern Pinball VENOM PRO Service And Operation Manual

Table of Contents

Advertisement

4.20 POWER DISTRIBUTION BOARD

520-8096-00
ID
Type
Pin Description
CN1 .156 in 7-Pin Housing
1
+48 VDC IN
2
+48 VDC IN
Plug: 045-5259-07
3
+48 VDC IN
Pin: 055-5331-00
4
Key (n/c)
Key: 060-5013-00
5
Ground
6
Ground
7
Ground
CN2 .093 in 3-Pos Plug
1
Line In (100-240 VAC)
2
Neutral
Plug: 045-5003-03
3
Earth Ground
Pin: 055-5013-09
CN3 0.084 in 4-Pos Plug
1
+48 VDC to CPU Node
2
Door Interlock Switch Status GRY/RED
Plug: 045-5200-04
3
Line Voltage Status
Pin: 055-5033-08
4
Ground
CN4 0.084 in 6-Pos Plug
1
Door Interlock Switch +48V
2
Door Interlock Switch +48V
Plug: 045-5200-06
3
Switched 48V Out (to Node 1) GRY/YEL
Pin: 055-5033-08
4
Door Interlock Return Ground GRY/RED
5
Door Interlock Return Ground -
6
Ground (to Node 1)
CN5 0.084 in 12-Pos Plug
1
Switched 48V Node Power
2
Switched 48V Node Power
Plug: 045-5200-12
3
Switched 48V Node Power
Pin: 055-5033-08
4
Switched 48V Node Power
5
Switched 48V Node Power
6
Switched 48V Node Power
7
Node Ground
8
Node Ground
9
Node Ground
10
Node Ground
11
Node Ground
12
Node Ground
CN6 .156 in 3-Pos
1
Ground
Plug: 045-5259-03
2
Ground
Pin:055-5331-00
3
+12VDC
(18awg)
CN7 .084 2-Pos
1
+48 VDC to Topper Node
Plug: 045-5200-02
2
Ground
Pin:055-5033-08
© MARVEL
ELECTRONIC PINOUTS AND SCHEMATICS

4.21 POWER PLUG WIRING

CAUTION
TO MAINTAIN SAFETY, GROUND WIRE FROM LINE FILTER
IS TO BE MOUNTED FIRST ON GROUNDING STUD AND
SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE
ATTACHED TO GROUNDING STUD.
REPLACE ALL FUSES WITH CORRECT CURRENT RATINGS!
NORTH AMERICA
Wire Color
GRY
GRY
GRY
-
BLK
POWER SUPPLY
BLK
POWER DIST.
BLK
BILL VALIDATOR
(USER INSTALLED OPTION)
BLK
WHT
INTERNATIONAL
*MFG NOTES:
GRN
1.
ALL DISCREET WIRE IS 16AWG 600V, UL 1015, CSA TYPE TEW.
2.
NEMA 5-15 OUTLET HAS 14AWG 600V WIRE, UL 1015, CSA TYPE TEW.
GRY
3.
GROUND WIRE FROM LINE FILTER IS TO BE MOUNTED FIRST ON GROUNDING STUD
AND SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED TO
GROUNDING STUD.
4.
CABLE ARE TO BE MANUFACTURED IN A UL CERTIFIED FACILITY. VENDOR IS TO
PROVIDE A SIGNED U.L. CERTIFICATE OF COMPLIANCE WITH FIRST ARTICLE.
VIO
BLK
GRY
POWER SUPPLY
-
POWER DIST.
LINE CORDS
BLK
GRY
*MFG NOTES:
Part Number
GRY
1.
ALL DISCREET WIRE IS 16AWG 600V, UL 1015, CSA TYPE TEW.
034-6012-00
2.
GROUND WIRE FROM LINE FILTER IS TO BE MOUNTED FIRST ON GROUNDING STUD
GRY
AND SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED TO
034-6012-01
GROUNDING STUD.
GRY
3.
CABLE ARE TO BE MANUFACTURED IN A UL CERTIFIED FACILITY. VENDOR IS TO
034-6012-02
PROVIDE A SIGNED U.L. CERTIFICATE OF COMPLIANCE WITH FIRST ARTICLE.
GRY
034-6012-03
GRY
034-6012-04
BLK
034-6012-05
BLK
034-6012-06
BLK
034-6012-07
BLK
034-6012-08
BLK
034-6012-09
BLK
LINE FUSES
-
-
Line Voltage (Region)
-
120V (North America)
220/240v (Europe, Australia,
GRY
UK)
BLK
VENOM PRO MANUAL 500-55U1-01
NORTH AMERICA
NEMA 5-15 PREWIRED OUTLET
L
LINE FILTER
G
R1
N
GROUNDING
STUD
INTERNATIONAL
ON/OFF SW
L
LINE FILTER
G
R1
N
GROUNDING
STUD
ON/OFF SW
Description
Line Cord, 3m, 5-15P USA
Line Cord, 3m, CEE77P EUROPE
Line Cord, 3m, BS1363P United Kingdom
Line Cord, 3m, AS-NZS4417P Australia
Line Cord, 3m, CEI23-16P Italy
Line Cord, 3m, SEV1011P Switzerland
Line Cord, 3m, JIS8303P Japan
Line Cord, 3m, SI32P Israel
Line Cord, 3m, BS546P S Africa, India
Line Cord, 3m, IS6538P S. India
Fuse
Type
Current
8 A
Slow Blow 30G
5 A
Slow Blow 5 x
20mm
FUSE
R1: 10M OHM 0.5W
FUSE
05/02/14
AC WIRI
1.00"
2.00"
1:1
R1: 10M OHM 0.5W
SPIKE
05/02/14
1.00"
2.00"
1:1
Part Number
200-5000-05
200-5003-00
37