Download Print this page

Troubleshooting - Honeywell 4202 User Manual

Source 12 basis weight sensor

Advertisement

 Check receiver voltages
Check the receiver voltages on the backplane against table below

Troubleshooting

This chapter covers possible issues with the basis weight sensor. It is divided into two sections:
• Alarm based troubleshooting: Troubleshooting steps to be taken in response to a specific alarm generated in
the Experion MX system.
• Non-alarm based troubleshooting: Troubleshooting steps that may not be related to a specific alarm in the
Experion MX system
Alarm based troubleshooting
No BW Signal
Symptom
BW signal below background
voltage (usually 15 – 30 mV)
BW Signal High
Symptom
BW receiver signal above
maximum allowed voltage
(maximum is 10 V)
High Closed Safe Volts
Possible cause
No ± 12 V power generated on
receiver
Amplifier not installed or broken
Loose terminal connection
Possible cause
Amplifier OpAmp broken
Amplifier gain set too high
Broken compensator
Solutin
Check receiver voltage
Check receiver voltage , replace
amplifier
Check wiring
Solutin
Check receiver voltage
Change gain
Check compensator on receiver
part

Advertisement

loading