ENROLL THE SENSOR
Enroll the sensor in the control panel prior to its usage in the
system. Refer to the control panel instructions for programming
details. Program the sensor as an "RF" type (supervised
RF) device.
To enroll: connect the battery and wait for power up to end
(see LED Indications table). When prompted for the serial
number, activate the sensor (wave a hand in front of the lens)
to enroll the sensor.
Loop 1
Pulse count 2; Up to 80 lbs. Animal Immunity

LED INDICATIONS

Condition
Indicator LED
Power Up
Blinks once per second (for < 45 seconds)
Walk Test
ON for 3 seconds = Loop 1 / Low Sensitivity Alarm
Flickers rapidly for 3 seconds = walk test period ended
MOUNT THE SENSOR (See page 1)
Before mounting the transmitter permanently, conduct Go/No
Go tests (see control panel manual) to verify adequate signal
strength and reorient or relocate the sensor if necessary.
For Animal (Pet) Immunity:
• Install the sensor where animals cannot come within 6 ft
(1.8 m) of the sensor by climbing on furniture or other
objects.
• Aim the sensor away from stairways, furniture or other
objects that can be climbed on by animals.
• Do not use optional swivel mount brackets.
WALK TESTING
The 10 minute walk test mode begins after power up, and can
be restarted by removing and replacing the battery.
As you walk through the detection pattern, the sensor LED will
light for 3 seconds to indicate each alarm detection.
Note: In walk test mode all transmissions will be sent as they
occur. During normal operation, only one transmission
sequence will occur within a 3-minute period to conserve
battery life.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the
Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's
authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC
requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is,
in strict accordance with the manufacturer's instructions, may cause interference to radio and television
reception. It has been type tested and found to comply with the limits for a Class B computing device in
accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable
protection against such interference in a residential installation. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
If using an indoor antenna, have a quality outdoor antenna installed.
Reorient the receiving antenna until interference is reduced or eliminated.
Move the radio or television receiver away from the receiver/control.
Move the antenna leads away from any wire runs to the receiver/control.
Plug the receiver/control into a different outlet so that it and the radio or television receiver are on
different branch circuits.
Consult the dealer or an experienced radio/TV technician for help.
 2009 Honeywell International Inc. Honeywell is a registered trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved. Assembled in Mexico.
For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or
Please contact your local authorized Honeywell representative for product warranty information.
PRELIMINARY DRAFT 8/24/09

TROUBLESHOOTING

Problem: The system displays a "low battery" message.
Solution: Replace the battery within 7 days.

SPECIFICATIONS

Power: Battery* (included).
Battery Life, years (typical):
RF Frequency:
Operating Temperature:
(for indoor use environment)
Relative Humidity, no
condensation:
Detectable Walk Rate:
Temperature Compensation:
* Battery Caution: Risk of fire, explosion and burns. Do not recharge,
disassemble, heat above 212° F (100° C), or incinerate. Dispose of
used batteries promptly. Keep away from children.
APPROVALS / LISTINGS
• FCC part 15, Class B verified
• IC, ICES-003, Class B verified
• C-Tick
• CE
• SIA-PIR-01
Passive Infrared detector standard features
for false alarm immunity.
• cETLus Listed
COMPLIANCE NOTES
• Product must be tested at least once each year.
• Product must be installed within the protected area only.
IC NOTICE: This Class B digital device complies with the Canadian ICES-003.
Cet appareil numérique de la Classe B est conforme à la norme NMB-003 du Canada.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules and RSS-210 of the IC rules. Operation is
subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired
operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son
fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d'interférences
nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une
réception indésirable.
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
www.honeywell.com/security
- 2 -
1 x 3 V, Lithium;
CR123A / DL123 / DL 123A / 466
5
345 MHz
14° to 131° F (-10° to 55° C)
95% max.
0.7 – 7ft/Sec. (0.2 – 2.0m/Sec.)
Advanced Dual Slope
Ê800-04182V1,Š
P/N 800-04182V1 Rev A
3/12

Advertisement

loading