Download Print this page

Kohler HYDRO-TOWER 200 Installation Instructions Manual page 9

Pneumatic in-wall tank with frame short height
Hide thumbs Also See for HYDRO-TOWER 200:

Advertisement

9. To remove the flush valve Security tab at the
rear of the cistern, pull forward on the tab and lift out.
11. Remove discharge valve for cleaning or adjusting.
Cleaning the mesh filter
●To clean the mesh filter, release by rotating counter clockwise then pull free.
Rinse clean and fit before replacing the flush vavle.
Close
Tighten
Open
A
Adjusting Inlet Valve
Raise or lower the water level in the tank by adjusting the float
level with the adjusting screw. Turn clockwise to increase the
water level and counter clockwise to reduce. The water level
must align with the water line mark in the tank.
Adjusting Outlet Valve
● If the flush volume is incorrect, the flush volume and overflow
level of the tank can be altered by adjusting the valve:
For full flush, adjust the bottom slide adjustment switch. Adjust
up to increase volume.
For reduced flush adjustment, adjust the float level. Adjust up
to increase volume. The reduced flush water lower level will
be at the bottom of the float.
1310920-A02-A
Security tab
Open
Corner
Mesh filter
B
10.With the flush valve fastener removed, the flush valve can
be lifted out.
Outlet valve
Tighten
Close
C
Spacer
Adjustment switch
-9 -
Outlet valve
Outlet valve
Inlet valve
Adjusting screw
Control pole
Floating box
Drainage valve