Download Print this page

Kohler HYDRO-TOWER 200 Installation Instructions Manual

Pneumatic in-wall tank with frame short height
Hide thumbs Also See for HYDRO-TOWER 200:

Advertisement

Quick Links

THANK-YOU FOR CHOOSING KOHLER COMPANY
We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation.
If you encounter any installation or performance problems, please don't hesitate to contact us. Our phone numbers are listed on
the final page. Thanks again for choosing Kohler Company.
BEFORE YOU BEGIN
Read the installation guide carefully and install the product accordingly.
The product information contained in this publication is correct at the time of printing. Kohler Co. reserves the right to
implement changes to this guide, product characteristics, packaging and availability at any time without further notice.
Do not use corrosive cleaners or solvents in or on the tank. This may damage the tank. Mild detergent can be used.
Do not use any spare parts which are not supplied by Kohler. Kohler will not be responsible for any damage due to the
installation of non approved spare parts.
Observe all local plumbing and building codes. Installation shall be in accordance with AS/NZS 3500 and AS/NZS 6400.
WARNING
This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 72.5psi (500 kPa) maximum.
Any installations where the supply pressure is outside of these limits will not be covered by warranty.
ORDERING INFORMATION
HYDRO-TOWER 200 PNE IWT With Frame 3/4.5 ................................................................................................. 20007A-PNE-NA
PEBBLE Pneumatic In-Wall Tank Faceplate (For Separate Purchase) ...................................................................20341T-PNE-CP
SPECIFICATIONS
Liters per flush
Operating temperature
range
RECOMMENDED TOOLS AND MATERIALS
10'' Adjustable
Wrench
Tubing Cutter
Safety Glasses
1310920-A02-A
20007A-PNE-NA
Environmental temperature:
Water temperature:
Supply
Tape
Shut-off
Measure
Valve
Drill and
assorted bits
HYDRO-TOWER 200
Full flush volume: 4.5L
Half flush volume: 3L
Level
Sponge
Plus:
Connector
Metal File
1/2'' Nut Driver/Socket
Saw
Screwdriver
M8 Coach/TEK Screws x 4
Apprpriate fasteners for masonary
or timber construction.
-1-
INSTALLATION INSTRUCTIONS
PNEUMATIC IN-WALL TANK
WITH FRAME (SHORT HEIGHT)
20007A-PNE-NA
20341T-PNE-CP
Pipe wrench

Advertisement

loading

Summary of Contents for Kohler HYDRO-TOWER 200

  • Page 1 Do not use corrosive cleaners or solvents in or on the tank. This may damage the tank. Mild detergent can be used. Do not use any spare parts which are not supplied by Kohler. Kohler will not be responsible for any damage due to the installation of non approved spare parts.
  • Page 2 ROUGH-IN 20007A-PNE-NA installed with 20341T-PNE-CP Note: Set the final cistern height to achieve the required pan height. 150~185 Air hose Ø90 85~93 Finished floor UNIT: mm A1) INSTALLATION FOR IN-WALL TANK WITH FRAME The In-wall tank with frame (20007A-PNE-NA) should be used with wall hung toilets. Note: Minimum cavity (stud pocket) dimensions for installation of the in-wall tank, 555mm wide, 170mm deep.
  • Page 3 4. Loosen the nut securing the adjustable bracket and extend to the required height.Tighten the nut. 5. Fit the toilet fixing bolts in the required position to suite the pan fixing holes (180mm or 230mm) Base bracket refer to toilet installation instruction. If no fixing Pan fixing kit is supplied with the pan, use the fixing kit Frame screw...
  • Page 4: S-Trap Installation

    4. Fit the waste pipe and the flush pipe covers. Flush pipe cover Waste pipe cover Waste connector Waste pipe support bracket S-trap installation Tank frame 1. Loosen the screw on waste pipe support bracket if required. S-trap 2. Insert S-trap waste pipe into the waste pipe waste pipe support bracket.
  • Page 5 A3) FACE PLATE/ACVESS PANEL INSTALLATION METHODS There are four ways to install access panel: Method one: Press from top Method two: Remote locking plate installation Method three: Remote installation of flush button shield Method four:Press from front: fix four pinch plates with screws Important: For methods two and three,remote access panel installation a removable panel must be installed either to the top or front of the cistern access to the cistern parts/valves for maintenance purposes.
  • Page 6 6. To lock the bolts in position turn the bolt counter-clockwise until the tab on the bolt head is vertical to LOCK mark. Note: Do not use excessive force - hand tighten only. 7. Trim the length of the locking bolts if required. Locking plate Locking plate bolt Faceplate...
  • Page 7 A4) INSTALLATION OF TOILET 1. Fit the flush pipe connector to the flush pipe inlet on the toilet. 2. Fit the waste pipe connector to the waste pipe Inlet pipe Mark showing position outlet on the toilet. of toilet rear 3.
  • Page 8 3. Carefully loosen the four locking screws by rotating them clockwise until the screw slots align with open tabs. Warning: No tools or excessive force should be used to rotate the locking screws to the ‘’OPEN’’ position. Locking plate Locking bolt 4.
  • Page 9 9. To remove the flush valve Security tab at the 10.With the flush valve fastener removed, the flush valve can rear of the cistern, pull forward on the tab and lift out. be lifted out. Security tab Outlet valve 11. Remove discharge valve for cleaning or adjusting. Outlet valve Outlet valve Cleaning the mesh filter...
  • Page 10: Troubleshooting Procedures

    CONTACT & WARRANTY INFORMATION For warranty information, please visit our website New Zealand Australia www.kohler.co.nz www.kohler.com.au CALL US FOR HELP NEW ZEALAND AUSTRALIA KOHLER NZ LTD KOHLER CO. Free Ph: Free Fax: 0800 664 488 (1 800 564 537) www.kohler.co.nz www.kohler.com.au 1310920-A02-A -10-...

This manual is also suitable for:

20007a-pne-na20341t-pne-cp