Technical Specifications; Power Supply Specifications; Failsafe Relay Specifications; Supported Networking Standards - Siemens SIMATIC NET RUGGEDCOM M2200 Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM M2200:
Table of Contents

Advertisement

Technical Specifications

This section details the specifications and operating conditions of the device.
5.1

Power Supply Specifications

The RUGGEDCOM M2200 can be equipped with the following power supplies:
Electrical hazard – risk of damage to the device
Make sure power input to the device is within the specified input range.
5.2

Failsafe Relay Specifications

Maximum Switching
Voltage
Rated Switching
Current
Maximum Switching
Capacity
5.3

Supported Networking Standards

Standard
IEEE 802.3u
IEEE 802.3x
IEEE 802.3z
IEEE 802.3ab
IEEE 802.3ad
IEEE 802.1D
IEEE 802.1D
IEEE 802.1p
IEEE 802.1Q
IEEE 802.1w
RUGGEDCOM M2200
Installation Manual, 11/2022, C79000-G8976-1044-19
NOTICE
250 VAC, 125 VDC
2 A @ 250 VAC, 0.15 A @ 125 VDC, 2 A @ 30 VDC
150 W, 500 VA
10 Mbps Ports
 
ü
 
 
 
ü
ü
ü
ü
ü
100 Mbps
1000 Mbps
Ports
Ports
 
ü
ü
ü
 
ü
 
ü
 
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
Description
100BaseTX/100BaseFX
Flow Control
1000BaseLX
1000BaseTx
Link Aggregation
MAC Bridges
Spanning Tree Protocol (STP)
Class of Service (CoS)
VLAN (Virtual LAN) Tagging
Rapid Spanning Tree Protocol
(RSTP)
5