Philio PAN35 Operating Manual, Installation Steps

Philio PAN35 Operating Manual, Installation Steps

In wall dual relay(1 way) switch module
Hide thumbs Also See for PAN35:

Advertisement

Quick Links

PAN35
In Wall Dual relay(1 way) switch module
FCC ID : RHHPAN35
This in-wall switch module is a transceiver which is a Z-Wave Plus
and is fully compatible with any Z-Wave
module can easily hide itself into the wall box and that will be good for the house
decoration.
There are many kind of application by using the module to switch Load On and Off,
This in-wall switch module is a transceiver which is a Z-Wave Plus
and is fully compatible with any Z-Wave
module can easily hide itself into the wall box and that will be good for the house
decoration.
There are many kind of application by using the module to switch Load On and Off,
one main application is the light control. If connect the com port directly to AC Line
TM
enabled device
TM
enabled network. Mini size design let the
TM
enabled device
TM
enabled network. Mini size design let the
terminal, the new smart relay calibration technology can reduce the inrush current
caused by the load and let the module work perfectly with many kind of light like
incandescent, fluorescent and LED light. This module can also connect to alternative
power supply like DC 12V to switch on/off 12V MR-16 light as follow picture.
Specification
Operating Voltage
100 ~240VAC /50Hz/60Hz
24-60V DC ±10%
Maximum Load
6.5A (230Vac/120Vac) (Resistive load)
Range
Minimum 40 m in door 100m outdoor line of sight
Operating Temperature 0°C ~ 40°C
Frequency Range
PAN35-1: 868.40MHz; 869.85MHz(EU) /
PAN35-2: 908.40MHz; 916.00MHz(USA/Canada) /
PAN35-3: 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP)
PAN35-IL: 916.00MHz(Israel)
** Specifications are subject to change and improvement without notice.
Troubleshooting
Symptom
Cause of Failure
The Switch not working and
1. The Switch is not connect
LED off
to the Main power
2. The Switch break down
The Switch LED
Check if the load connect
1
Recommendation
1. Check power connections
2. Don't open up the Switch and
send it for repair.
Set the ON/OFF switch of the load

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAN35 and is the answer not in the manual?

Questions and answers

Summary of Contents for Philio PAN35

  • Page 1 FCC ID : RHHPAN35 PAN35-2: 908.40MHz; 916.00MHz(USA/Canada) / This in-wall switch module is a transceiver which is a Z-Wave Plus enabled device PAN35-3: 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP) and is fully compatible with any Z-Wave enabled network. Mini size design let the PAN35-IL: 916.00MHz(Israel) module can easily hide itself into the wall box and that will be good for the house ** Specifications are subject to change and improvement without notice.
  • Page 2: Installation Steps

    (230Vac/120Vac) (Resistive load) ELECTRICAL SHOCK. Installation Steps 1. Connect PAN35 to AC N and L and COM connect to L. For Instruction to http:// www.philio-tech.com 2. Connect Load1 and Load2 to NO1 and NO2. 3. Connect external Switch to S1 and S2.
  • Page 3 Have Z-Wave Controller entered One press one flash 2. Do not exceed the max rating (Inclusion) inclusion mode. 2. Pressing Include button of PAN35 Adding to Z-Wave Network three times within 2 seconds will enter inclusion mode. In the front casing, there is an on/off button with LED indicator below which is used to...
  • Page 4: Led Indication

    Sometimes people are not easy to execute exclusion or inclusion especially when 3. Do not locate the Switch where exists combustible substances or any source of PAN35 already installed in a wall box. To solve this issue, PAN35 support a special heat, e.g. fires, radiators, boiler etc.
  • Page 5 2. Connect the wall switch to the PAN35 as Fig1 . Binary Switch Report Command: 3. There are 3 mode PAN35 can be configured to match different kind of wall Report OFF:[Command Class Switch Binary, Switch Binary Report, Value switch, please refer to 3-1 Edge / Pulse / Edge-Toggle mode which described in...
  • Page 6 For group 3, the Switch will report ON/OFF status of Relay2 You may get the ON/OFF state from every endpoint, when endpoint set to 1, PAN35 will reply ON(0xFF) either Relay 1 is ON, report OFF (0x00) when Relay 1 is 2-1 Auto report to Grouping 1 ~3(Maximum Node 5) OFF.
  • Page 7 Relay2 ON/OFF by setting endpoint to 2. owner doesn’t support multi Channel this value will be 0) The example of the command show that switch off relay2 of PAN35 (Bit Address+Destination End Point = 0x01) (Bit Address =0;Destination End Point range from 1~2)
  • Page 8 3-3 Auto off timer: 0x7FFF timer function Whenever PAN35 switches to on, the auto off timer begin to count down. After the 1-0x7FFF : 1s ~ timer decrease to zero, it will switch to off automatically. However if Auto off timer 32767s is set as 0, the auto off function will be disabled.
  • Page 9 Manufacturer Specific Highest granted Security Class 5. Firmware update over the air (OTA) PAN35 is based on 700 series SoC and supports Firmware Update Command Class, Multi Channel Association Highest granted Security Class it can receives the updated firmware image sent by controller via the Z-wave RF me-...
  • Page 10: Fcc Interference Statement

    They can take this product for environmental safe recycling. may cause undesired operation. Company of License Holder:Philio Technology Corporation FCC Caution: Any changes or modifications not expressly approved by the party re- Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New sponsible for compliance could void the user's authority to operate this equipment.

Table of Contents