Chapter 2 Planning And Engineering; Environmental Conditions - Nortel 1000 Hardware Installation Manual

Application gateway
Table of Contents

Advertisement

Chapter
Chapter 2
Planning and Engineering

Environmental Conditions

The following topics describe the environmental, grounding, and power
requirements of the Nortel Application Gateway 1000:
Environmental Conditions, page 7
Grounding, page 8
Power, page 9
The environment in which the Application Gateway operates must meet
the following general conditions:
Ventilating openings on the Application Gateway must be free of
obstructions.
Temperature must be maintained between 0° and 35° C (32° and
98° F).
Humidity must be between 5% and 95% at 30° C non-condensing.
The Application Gateway must not be subject to constant vibration.
The Application Gateway and other system equipment must be
located at least 12 ft. (3.66 m) away from sources of electrostatic,
electromagnetic, or radio frequency interference. These sources can
include:
power tools
appliances (such as vacuum cleaners)
office business machines (such as copying machines)
elevators
air conditioners and large fans
radio and TV transmitters
Application Gateway Hardware Installation Guide
7