Swegon PARAGON Wall VAV Installation, Commissioning Maintenance

Swegon PARAGON Wall VAV Installation, Commissioning Maintenance

Hide thumbs Also See for PARAGON Wall VAV:

Advertisement

Quick Links

PARAGON Wall VAV
Installation - Commissioning - Maintenance
Contents
Application area .................................................. 2
General....................................................................... 2
Contents ..................................................................... 2
Protective equipment .................................................. 2
Electrical safety ........................................................... 2
Handling ..................................................................... 2
Installation .................................................................. 2
Cleaning ..................................................................... 2
Cleaning of electrical components ............................. 2
Service/maintenance ................................................... 2
Environment and waste disposal ................................. 2
Disposal of the product ............................................... 2
Product warranty ........................................................ 2
Dimensions and weights .................................... 3
Installation .......................................................... 4
Size of the opening ..................................................... 4
Suspension ................................................................. 5
Connection - Water .................................................... 7
Connecting water ....................................................... 7
Water quality .............................................................. 8
Connection - Air ......................................................... 9
Grille installation ......................................................... 9
Supply and extract air kit .......................................... 10
Connections control equipment ...................... 11
Room controller, LOCUS ............................................ 13
Sensor module .......................................................... 14
Maintenance ...................................................... 15
Symbols
Warning/Caution!
See also the following documents at www.swegon.com:
- PARAGON Wall VAV Product datasheet
- VAV Modbus
- Comfort modules, operation and maintenance (IOM)
- LOCUS Product datasheet
- LOCUS Instructions for Use (IOM)
17/01/2023
Art. 942428075

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PARAGON Wall VAV and is the answer not in the manual?

Questions and answers

Summary of Contents for Swegon PARAGON Wall VAV

  • Page 1: Table Of Contents

    Contents ..............2 Warning/Caution! Protective equipment ..........2 Electrical safety ............2 Handling ..............2 See also the following documents at www.swegon.com: Installation ..............2 Cleaning ..............2 - PARAGON Wall VAV Product datasheet Cleaning of electrical components ......2 - VAV Modbus Service/maintenance ...........
  • Page 2: Application Area

    Swegon AB; or (2) the The product must be handled with care. serial number on the product has been made illegible or is missing.
  • Page 3: Dimensions And Weights

    2.47 1400 L 27.6 31.2 2.46 1400 R 27.6 31.2 2.47 0.65 1400 L 27.6 31.2 2.46 0.64 1400 R 27.6 31.2 2.47 1400 L 27.6 31.2 2.46 *Added weight for control equipment: 0.84 kg 01/17/2023 Swegon reserves the right to alter specifications.
  • Page 4: Installation

    2 0 0 > 2 0 3 0 0 0 / 1 4 / 1 1 0 8 0 0 231 (+0-20) 569 (+0-20) 92,5 92,5 231 (+0-20) 569 (+0-20) 92,5 92,5 Swegon reserves the right to alter specifications. 17/01/2023...
  • Page 5: Suspension

    PARAGON Wall VAV Suspension c / c = B c / c = A L (mm) A (mm) B (mm) 23,5 1100 1078 1400 1378 01/17/2023 Swegon reserves the right to alter specifications.
  • Page 6 PARAGON Wall VAV Swegon reserves the right to alter specifications. 17/01/2023...
  • Page 7: Connection - Water

    A1 = Cooling water, supply A2 = Cooling water, return A2 = Cooling water, return B1 = Heating water, supply B1 = Heating water, supply B2 = Heating water, return B2 = Heating water, return 01/17/2023 Swegon reserves the right to alter specifications.
  • Page 8: Water Quality

    PARAGON Wall VAV Water quality Connection of CCO valve Swegon recommends water quality according to VDI 2035-2 for both the heating and cooling systems. In order to maintain the oxygen content in the water below the levels (<0.1 mg/l) prescribed in VDI 2035-2, it is recommended to install a vacuum degasser, particularly in the cooling system where it’s more challenging to dissolved gas.
  • Page 9: Connection - Air

    Back view Connection dimensions, air Length (mm) Air connection (mm) 800, 1100, 1400 Ø 125 Grille installation C l i c k ! 01/17/2023 Swegon reserves the right to alter specifications.
  • Page 10: Supply And Extract Air Kit

    PARAGON Wall VAV Supply and extract air kit Supply air Extract air Swegon reserves the right to alter specifications. 17/01/2023...
  • Page 11: Connections Control Equipment

    B. Connection on slave product 3xRJ12 Sensor module LOCUS Room controller LOCUS Room controller Inputs Outputs Controller outputs Max 48 VA Modbus Actuator Inputs Outputs Max 48 VA Max 48 VA Actuator Modbus 01/17/2023 Swegon reserves the right to alter specifications.
  • Page 12 Modular 6/6 RJ12 Modular 6/6 RJ12 | 22 | 23 | 24 | 25 | | 22 | 23 | 24 | 25 | MB id 4 MB id 1 Master Slave id 1 Swegon reserves the right to alter specifications. 17/01/2023...
  • Page 13: Room Controller, Locus

    Machinery Directive: 2006/42/EEC For more detailed information about LOCUS room controller. EMC Directive: 2014/30/EU See documentation at www.swegon.com RoHS Directive: 2002/95/EC • LOCUS Product datasheet Vibrations: EN-60721-3-3 • LOCUS Instructions for Use (IOM) 01/17/2023 Swegon reserves the right to alter specifications.
  • Page 14: Sensor Module

    PC with the help of Cable Switch for termination resistance. On the last converter USB-RJ12 sensor module in the circuit switch 1 is set to On. Swegon reserves the right to alter specifications. 17/01/2023...
  • Page 15: Maintenance

    PARAGON Wall VAV Maintenance 01/17/2023 Swegon reserves the right to alter specifications.
  • Page 16 PARAGON Wall VAV Swegon reserves the right to alter specifications. 17/01/2023...

Table of Contents