Swegon PARAGON Wall VAV Installation, Commissioning Maintenance
Swegon PARAGON Wall VAV Installation, Commissioning Maintenance

Swegon PARAGON Wall VAV Installation, Commissioning Maintenance

Hide thumbs Also See for PARAGON Wall VAV:

Advertisement

Quick Links

PARAGON Wall VAV
Installation - Commissioning - Maintenance
Content
Application area .................................................. 2
General....................................................................... 2
Contents ..................................................................... 2
Protective equipment .................................................. 2
Electrical safety ........................................................... 2
Handling ..................................................................... 2
Installation .................................................................. 2
Disposal ...................................................................... 2
Cleaning ..................................................................... 2
Service/maintenance ................................................... 2
Product warranty ........................................................ 2
Dimensions and weight...................................... 3
Installation .......................................................... 4
Cutout dimensions ...................................................... 4
Suspension ................................................................. 5
Water connection ....................................................... 7
Connecting water ....................................................... 7
Air connection ............................................................ 8
Connection dimensions air .......................................... 8
Supply and extract air kit ............................................ 9
Room unit, RU .......................................................... 10
Wiring diagram ..........................................................11
Grilles assembly ........................................................ 13
Maintenance ...................................................... 14
Symbols
Warning/Caution!
23/11/2021
Art. 942428075

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PARAGON Wall VAV and is the answer not in the manual?

Questions and answers

Summary of Contents for Swegon PARAGON Wall VAV

  • Page 1: Table Of Contents

    PARAGON Wall VAV Installation – Commissioning – Maintenance 23/11/2021 Art. 942428075 Content Symbols Application area ..........2 General............... 2 Contents ..............2 Warning/Caution! Protective equipment ..........2 Electrical safety ............2 Handling ..............2 Installation ..............2 Disposal ..............2 Cleaning ..............
  • Page 2: Application Area

    (1) The product is repaired, modified or changed, unless such repair, modification or change has been approved by Swegon AB; or (2) the serial number on the product has been made illegible or is missing.
  • Page 3: Dimensions And Weight

    8 0 1 / 1 1400 R 27.6 31.2 2.47 0.65 1400 L 27.6 31.2 2.46 0.64 1400 R 27.6 31.2 2.47 1400 L 27.6 31.2 2.46 *excl. weight for: Control equipment: 0,84 kg 23/11/2021 Swegon reserves the right to alter specifications.
  • Page 4: Installation

    2 0 0 > 2 0 3 0 0 4 0 5 5 / 1 / 1 1 0 8 0 5 439,4 23,5 (0+20) 92,5 92,5 439,4 (0+20) 23,5 92,5 92,5 Swegon reserves the right to alter specifications. 23/11/2021...
  • Page 5: Suspension

    PARAGON Wall VAV Suspension Length (mm) A (mm) B (mm) 778,2 222,5 c / c = B 1100 1078,2 222,5 1400 1378,2 222,5 c / c = A 23/11/2021 Swegon reserves the right to alter specifications.
  • Page 6 PARAGON Wall VAV Swegon reserves the right to alter specifications. 23/11/2021...
  • Page 7: Water Connection

    A1 = Cooling water, supply A2 = Cooling water, return A2 = Cooling water, return B1 = Heating water, supply B1 = Heating water, supply B2 = Heating water, return B2 = Heating water, return 23/11/2021 Swegon reserves the right to alter specifications.
  • Page 8: Air Connection

    The product has the air connection centered on the back of the product for easy access from both ends and back. View from the back Connection dimensions air Length (mm) Air connetion (mm) 800, 1100, 1400 Ø 125 Swegon reserves the right to alter specifications. 23/11/2021...
  • Page 9: Supply And Extract Air Kit

    PARAGON Wall VAV Supply and extract air kit Supply air kit Extract air kit 23/11/2021 Swegon reserves the right to alter specifications.
  • Page 10: Room Unit, Ru

    After a while, it changes back to showing temperature. SET: Room temperature setting value. Change the set- ting value by selecting + or -. Informative indication. Cooling is ON. Informative indication. Heating is ON. Swegon reserves the right to alter specifications. 23/11/2021...
  • Page 11: Wiring Diagram

    Sensor module A. Connection when a VOC sensor is used Inputs Outputs The outputs on the regulator Max 48 VA Max 48 VA ModBus Motor Inputs Outputs Max 48 VA Motor ModBus 23/11/2021 Swegon reserves the right to alter specifications.
  • Page 12 Modular 6/6 RJ12 Modular 6/6 RJ12 | 22 | 23 | 24 | 25 | | 22 | 23 | 24 | 25 | MB id 4 MB id 1 Master Slave id 1 Swegon reserves the right to alter specifications. 23/11/2021...
  • Page 13: Grilles Assembly

    PARAGON Wall VAV Grilles assembly C l i c k ! 23/11/2021 Swegon reserves the right to alter specifications.
  • Page 14: Maintenance

    PARAGON Wall VAV Maintenance Swegon reserves the right to alter specifications. 23/11/2021...

Table of Contents