Swegon CASA W100 EC Instructions For Installation, Operation And Maintenance

Swegon CASA W100 EC Instructions For Installation, Operation And Maintenance

Table of Contents

Advertisement

Quick Links

Swegon CASA
®
W100 EC, version B
Instructions for Installation, Operation and Maintenance
W100B_f_EN-m

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CASA W100 EC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Swegon CASA W100 EC

  • Page 1 Swegon CASA ® W100 EC, version B Instructions for Installation, Operation and Maintenance W100B_f_EN-m...
  • Page 2: Table Of Contents

    5.6.9 Ventilation unit model ..........13 5.7 Installation and service ...........13 5.7.1 Alarm/Service reminder ..........14 5.7.2 Clock ................14 5.7.3 Temperature ...............14 5.7.4 Measurements ............14 5.7.5 Control functions ............14 N.B.! The manual was originally written in Finnish. www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 3: Important Information

    Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 4: Quick Guide

    The ventilation unit must not be operated means economical operation. This saves on without filters. Use only filters recommend- fan energy and the home heating system ed by Swegon in the ventilation unit. does not have to heat as much air during the cold season. Commissioning...
  • Page 5: Control From The Premium Cooker Hood

    2.2.2 Selection of fan speed Installation and service The fans inside the unit can be controlled to operate at three speeds: Home/Away/Boost. Select the required fan speed from the control panel. Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 6: General Description

    Premium control panel or a Premium cooker hood. The airflow boost time is selected manually to 30, 60 or 120 minutes from a Premium control panel. When the www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 7: Temperature

    The freeze protection alarm can the voltage is switched on, the shut-off dampers will be acknowledged from the Installation and service open again. A maximum of two damper motors can menu: Alarms. be connected. Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 8: Installation

    If the wall is composed of vertical studs and building boards. The wall must be reinforced with horizontal studs that can manage the weight of the unit. Swegon also recommends that the wall be insulated with mineral wool or similar insulation for preventing sound from propagating to other rooms.
  • Page 9: To Install The Ceiling Mounting Frame

    (on Secure the ventilation unit in position by tightening the screws the Econo model), through the ceiling mounting frame. Lift in its front panel. Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 10: Condensate Discharge

    • If the air inside the duct is colder than in the surroundings, When installing the unit, make sure that you provide the insulation should be protected by a moisture barrier. www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 11: To Seal Around Duct Penetration Collars

    For this reason, Swegon does not offer any recommendations. Most manufacturers of insulation material offer calculation programs for the calculation of sufficient and correct insulation.
  • Page 12: Application

    • The cooker hood damper. When preparing food or • Steady red glow: Alarm or a service reminder. carrying out a similar activity, a 30, 60 or 120 minute www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 13: Start Menu

    Base display Installation and • Switch off service Switch off • Factory settings Fireplace switch function • Controller See the Section: Weekly timer “Installation and • Functions service”. Unit model • Air heater Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 14: Alarm/Service Reminder

    (5 = 23 °C) • Select ON as the value for Negative pressure com- (6 = 26 °C) pensation, e.g. if the cooker hood has a differential Econo model’s thermostat for setting the temperature www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 15: Servicing

    The fan’s locking device 1. Extract air filter, G3 2. Supply air filter F7 3. Plate heat exchangers 4. Condensate connection 5. Outdoor air filter, PPI-20 Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 16: Alarms And Troubleshooting

    If the bypass damper for summertime operation is not completely closed, the air heater for reheat will not switch on. 1. Air heater, preheating www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 17: List Of Components

    11. Cover: DPw100RL 2. Fans (ventilation unit in left-hand model) • Lock: 61950 • Supply air fan: PWEC175R • Extract air fan: PEC119L 3. Air reheater, reheat (models with electric air heater): 50269 Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 18: Technical Details

    Supply airflow, Econo 100% 100% Airflow Airflow Extract airflow Extract airflow, Econo 100% 100% Airflow Airflow Thick line = SFP 2.0 or lower. Power consumption Power consumption, Econo 100% 100% Airflow Airflow www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 19: Acoustic Data

    Sound power level broken down into octave bands, L , db weighted sound wokt power level setting 63 Hz 125 Hz 250 Hz 500 Hz 1,000 Hz 2,000 Hz 4,000 Hz 8,000 Hz , db(A) Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 20: Connection Outputs

    230 V, 50 Hz, 5.4 A Fans 289 W 289 W Air heater, preheating 1000 W 1000 W Air heater, reheat 500 W Total output 1,800 W 1,300 W Fuse protection 10 A 10 A www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 21: Sizing Of The Water-Heated Air Heater

    9.5 Pressure loss in the air heater for reheat Swegon CASA w100 Econo Pressure loss in air heater Water-heated air heater Water-heated air heater + thermostat 250 dm³/h 0,02 0,03 0,04 0,05 0,07 dm³/s Water flow Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 22: Electrical Wiring Diagram

    5. Extract air fan’s DC contact 6. Control panel 7. Air heater, preheat, 1,000 W 8. Triac controller 9. Air heater, reheat, 500 W 10. Contact for bypass past the heat exchanger. 11. Inspection panel switch www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 23: Control Functions With Optional Items Of Equipment

    Priority 2: External supervision (DDC). Priority 3: normal operation from the control panel or the cooker hood. 1. To cooker hood, control panel or Modbus gateway 2. To cooker hood, control panel or Modbus gateway Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 24 Econo models. 8. Presence detector 9. Damper actuator for duct damper – A outdoor air duct** 10. Damper actuator for duct damper – B exhaust air duct** www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 25 40V, 500mA Close = alarm Open = no alarm 24VDC max 500mA Delivery demarcation Closed contact = Activation of the separate function Open contact = Normal use of the separate function Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 26: Control Diagram

    – If an overheating protection with manual reset trips, it can be reset by pressing a reset button above the air heater. – The automatic overheating protection of the fan will reset itself when the temperature has dropped below the setpoint. www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 27: W100 Ec Econo

    12 °C by the thermostat sensor. If the return water temperature drops 10 °C below the temperature by the type T6 sensor, the controller will switch off the supply air fan. The fan will starts again when the supply air temperature has risen above the value preset on the thermostat. Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 28: Dimensions

    • Set of replacement filters PW080FS • W100 Premium (L) PW100SL 1 pc. G3 • W100 Premium Econo (R) PW100ER 1 pc. F7 • W100 Premium Econo (L) PW100EL 1 pc. PPI-20 www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 29: Commissioning

    Filter guard not W100) In operation option Fireplace switch function (with fireplace switch) boost (with boost timer or presence detector) In operation option Outdoor temperature limit, for activation of air heater 15 °C Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 30 Date: The supply airflow must be 5-10 % lower than the extract airflow. Remember to explain the use of the item of optional equipment and how to service it to the user/caretaker! www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 31: Warranty Conditions

    If a defect is discovered during the warranty period, the client must without delay report the defect to the dealer or to an authorized service partner (www.swegon.com/casa). Specify which product has a fault (product model, type designation on the warranty card or on the product identification plate, serial number);...
  • Page 32: Eg Compliancy Declaration

    Person authorised to compile the technical documentation: Name: Rami Wiberg Address: Asessorinkatu 10, 20780 S:t Karins, Finland E-mail: rami.wiberg@ilto.fi Date: Kaarina 02.07.12 Signature: Peter Stenström Swegon ILTO Oy N.B.! The document’s original language is English. www.swegon.com/casa Swegon reserves the right to alter specifications.
  • Page 33 Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 34 Swegon reserves the right to alter specifications.
  • Page 35 Swegon reserves the right to alter specifications. www.swegon.com/casa...
  • Page 36 www.swegon.com/casa...

Table of Contents