Mode of operation: continuous operation with intermittent load Conformity: HiRay 30 complies with Directive 93 / 42 / EEC classifi ed as IIb and the national and international regulations for devices emitting ionizing radiation. Further information can be requested directly at EICKEMEYER®.
If you have any doubt, please consult EICKEMEYER®. • EICKEMEYER® is responsible for the safety of its products only if their maintenance, repair or modifi cation is carried out by EICKEMEYER® itself or by staff offi cially authorized by EICKEMEYER®.
Attached the tables from EMC reports: Table 1 The HiRay 30 is suitable for use in the specifi ed electromagnetic environment. The purchaser or user of the HiRay 30 should assure that it is used in an electromagnetic environment as described below:...
Page 7
USER MANUAL HIRAY 30 X - RAY MACHINE Table 2 The HiRay 30 is suitable for use in the specifi ed electromagnetic environment. The purchaser or user of the HiRay 30 should assure that it is used in an electromagnetic environment as described below:...
Page 8
SUPPORTING EQUIPMENT The HiRay 30 is intended for use in the electromagnetic environment specifi ed below. The customer or the user of the HiRay 30 should assure that it is used in such an environment Immunity Test EN 60601-1-2...
Recommended Separation Distance for non-LIFE SUPPORTING EQUIPMENT The HiRay 30 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the HiRay 30 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitter) and the HiRay 30 as recommended below, according to the maximum output power of the communications equipment.
80 to 125 kV 200 mA from 100 to 119 kV 100 mA from 120 to 125 kV Exposure Time from 2 ms to 1 sec from 2 ms to 1 sec T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
Weight 20 kg GENERATOR Weight 30 kg System 300 mm 1,500 mm 2,000 mm 300 mm 100 mm 720 mm 100 mm 780 mm 630 mm max. 950 mm 760 mm Picture 1: System T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
Picture 2: Monoblock Collimator The irradiation fi eld is delimited by the collimator Claymount 50250-11, equipped with timed LED illumination. Picture 3: Collimator T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
2 locking devices limiting the extraction (press the aforementioned towards the tray in order to remove it completely). Picture 5: Tray T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
In order to avoid the monoblock overheating, it’s necessary to pause between one exposure and the next. This simple procedure allows the dissipation of the produced heat. The following chart shows the minimum exposure pause, expressed in seconds, among consecutive exposures: T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
• Release the foot switch once the X-Ray exposure has been completed and wait till the “ready” button turns green again in order to repeat the procedure. T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
Selection 2 or 3 points technique. Screen Sensitivity of the intensifying screen. Mode Size of the patient according to its weight or thickness. T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
• The remaining parts, made of painted rolled plate, do not require special warnings, except for the area containing switches, pushbuttons, power sockets and thermomagnetic switch, where you should follow the same instruction of the touch screen panel and the collimator. T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
Page 22
USER MANUAL HIRAY 30 X - RAY MACHINE NOTES T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
Page 23
USER MANUAL HIRAY 30 X - RAY MACHINE NOTES T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
Page 24
GERMANY POLAND EICKEMEYER KG EICKEMEYER Sp. z o.o. Eltastraße 8 Al. Jana Pawła II 27 78532 Tuttlingen 00-867 Warszawa T +49 7461 96 580 0 T +48 22 185 55 76 F +49 7461 96 580 90 F +48 22 185 59 40 info@eickemeyer.de...
Need help?
Do you have a question about the HIRAY 30 and is the answer not in the manual?
Questions and answers