Signal Levels In The Venue System And Pro Tools - DigiDesign HDx TDM Record/Playback Option Manual

For venue systems
Table of Contents

Advertisement

(Direct Outputs Only) Activate and set the level for each Di-
4
rect Output by clicking its In button and dragging its
on-screen encoder in the Direct Out section.
Activating a Direct Output in the Directs page of the Patchbay
(Direct Outputs only) Click the Pickoff column in the Patch-
5
bay to specify one of the following the pickoff sources for each
Direct Output:
• top of channel (indicated by a "T")
• insert return (indicated by an "I")
• pre-fader (indicated by a lowercase "p") or post-fader (in-
dicated by an uppercase "P")
Click to display Pickoff menu
Specifying the channel Pickoff source
The available Direct Output pickoff points for Input
Channels and FX Returns can be configured globally
as pre- or post-fader in the Options > Pickoffs page.
Signal Levels in the VENUE System
and Pro Tools
0 dB on input meters of a VENUE system equal –20 dBFS. This
20 dB of mixer headroom helps prevent digital clipping and
distortion in live program material.
HDx does not provide independent gain control for the HDx
fixed outputs before they are split off to Pro Tools, so program
material coming into a VENUE system at 0 dB will be recorded
into Pro Tools at –20 dBFS.
For gain control of HDx outputs to Pro Tools, use Direct Out-
puts to route audio channels to HDx assignable outputs, and
adjust the gain on the Direct Output control for each channel.