Error code
Error message
458
SelfTest User Loader Integrity Error
459
SelfTest Main Application Integrity Error
460
SelfTest RNG Hardware Integrity Error
461
SelfTest DRNG Algorithm Integrity Error
462
SelfTest RSA Algorithm Integrity Error
463
SelfTest AES Algorithm Integrity Error
464
SelfTest HMAC Algorithm Integrity Error
465
SelfTest SHA Algorithm Integrity Error
466
SelfTest TLS Integrity Error
467
SelfTest FPGA Configuration Integrity Error
468
SelfTest FPGA CineLink. 2 Decryption Integrity Error
474
Security Tamper
475
Top Side Security Enclosure Open
476
Bottom Side Security Enclosure Open
477
Security Battery Event
478
Software Commanded Zeroization
481
Security Enclosure Not Armed
482
Physical Marriage Tamper
483
Logical Marriage Tamper
484
Marriage NOT Active
486
Service Door Tamper
487
Security Log Error
488
Security Battery Low Warning
489
Security Log Warning
500
IMB Comm Fail
510
IMB:System Error
511
IMB:Self Test Error
519
IMB:Certificate or Key Error
520
IMB:ICP Communications Status
537
IMB:RTC Error
543
IMB:FPGA Temperature out of range
550
IMB:Supply voltage out of range
574
IMB:Security Tamper
577
IMB:Security Battery Event
581
IMB:Security Enclosure Not Armed
582
IMB:Physical Marriage Tamper
583
IMB:Logical Marriage Tamper
584
IMB:Marriage NOT Active
586
IMB:Service Door Tamper
588
IMB:Security Battery Low Warning
700
Slave Comm Fail
701
Slave Status Fail
702
Lamp Lit Change
"Confidential, Do Not Duplicate without written authorization from NEC."
TROUBLESHOOTING
Description
Enigma is in FIPS error state.(Self test result)
Enigma is in FIPS error state.(Self test result)
Enigma is in FIPS error state.(Self test result)
Enigma is in FIPS error state.(Self test result)
Enigma is in FIPS error state.(Self test result)
Enigma is in FIPS error state.(Self test result)
Enigma is in FIPS error state.(Self test result)
Enigma is in FIPS error state.(Self test result)
Enigma is in FIPS error state.(Self test result)
Enigma is in FIPS error state.(Self test result)
Enigma is in FIPS error state.(Self test result)
Security tamper condition exists in Enigma.
Security tamper condition exists in Enigma.
Security tamper condition exists in Enigma.
Battery tamper condition exists in Enigma.
Destroyed Enigma key by software command.
Enigma security not armed.
Latched physical marriage tamper condition on Enigma
board.
Logical marriage tamper condition exists in Enigma.
Marriage between ICP and Enigma has NOT been 
established (active).
Latched service door tamper condition on Enigma board.
Security log is full and no more log entries can be created in
Enigma. It is the server's responsibility to avoid the issue.
Close to "(477) Security Battery Event".
Security log is almost full in Enigma.
Close to "(487) Security Log Error".
No communication with the IMB.
IMB Status error
IMB Status error
IMB Status error
IMB fails to do logical marriage to ICP when IMB powers up.
Because of no communications with ICP during logical
IMB RTC is "invalid".
IMB Status error
IMB Status error
Security tamper condition exists in IMB.
Battery tamper condition exists in IMB.
IMB security not armed.
Latched physical marriage tamper condition on IMB.
Logical marriage tamper condition exists in IMB.
Marriage between ICP and IMB has NOT been established
(active).
Latched service door tamper condition on IMB.
Close to "(577) IMB: Security Battery Event".
Failed to communicate with slave MCU.
Slave MCU is in unexpected status.
Lamp lit status becomes with unexpected state.
(It could appear while dual lamp mode.)
4-39
Solution
Check connections between the Enigma board and
NC-80LB, LAN I/F, and the firmware version.
Indicates Einigma security tamper is detected.
Indicates details of security tamper detection
information.
(Replace Enigma board.)
Replace Enigma board.
Press the [Arm Tamper] button that is availablein
the SETUP-Installation menu of the DCC to set the
Enigma Tamper function effective.
Press the [Re-Marriage] button that is availablein the
SETUP-Installation menu of the DCC to clear the
Enigma Physical Marriage event.
At the time of clearing, confirm that there areno
errors of Nos. 270 and 271.
Press the [Re-Marriage] button that is availablein the
SETUP-Installation menu of the DCC to establish
Logical Marriage between Enigmaand ICP.
At the time of Marriage, confirm that there areno
errors of Nos. 270 and 271.
Press the [Re-Marriage] button that is availablein the
SETUP-Installation menu of the DCC to establish
Logical Marriage between Enigmaand ICP.
At the time of Marriage, confirm that there areno
errors of Nos. 270 and 271.
Close all the SDT switches. After that, use a main
unit key and make a login (anyone of the Advanced
User, Installation, and Service) into the projector
main unit and clear the SDT event.
Replace Enigma board.
Charge up the battery cells for the EnigmaPWB.
Since the Security Log is almost full, log drainis
required on server side.
(This treatment is a server's role.)
Check the connection with IMB/IMS board, and LAN
I/F, firmware versions.
Check the IMB/IM PWB.
Replace the IMB/IM PWB.
Check the connection of IMB/IMS PWBs, LAN I/F,
and firmware version.
Confirm that the ICP PWB is normally started
Replace the IMB/IM PWB.
Check the IMB/IM PWB.
Replace the IMB/IM PWB.
Press the [Arm Tamper] button that is availablein the
SETUP-Installation menu of the DCC to set the IMB
Tamper function effective.
Press the [Re-Marriage] button that is availablein the
SETUP-Installation menu of the DCC to clear the
IMB Physical Marriage event.
At the time of clearing, confirm that there areno
errors of Nos. 270 and 271.
Press the [Re-Marriage] button that is availablein the
SETUP-Installation menu of the DCC to establish
Logical Marriage between IMBand ICP.
At the time of Marriage, confirm that there areno
errors of Nos. 270 and 271.
Press the [Re-Marriage] button that is availablein
the SETUP-Installation menu of the DCCto establish
Logical Marriage that has beencanceled between
IMB and ICP.
Close all the SDT switches. After that, use a main
unit key and make a login (anyone of the Advanced
User, Installation, and Service) into the projector
main unit and clear the SDT event.
Charge up the battery cells for the IMB/IMS PWBs.
Communication with Slave uC PWB failed.
Check the Slave uC PWB
The status of the Slave uC PWB is out of expectation.
Check the Slave uC PWB
Started in 2 lamps light-up mode, and succeeded in
one lamp activation.
In 2 lamps light-up status, only one lamp turned off.